Comparisons of multi b-value DWI signal analysis with pathological specimen of breast cancer

Previous studies have reported that the signal attenuation of diffusion weighted magnetic resonance imaging for tumor tissues displays a non‐monoexponential biexponential decay, and the apparent diffusion coefficients (ADCs) can be divided into a fast and slow diffusion component by using a simple b...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 68; no. 3; pp. 890 - 897
Main Authors Tamura, Takayuki, Usui, Shuji, Murakami, Shigeru, Arihiro, Koji, Fujimoto, Takashi, Yamada, Tamaki, Naito, Kumiko, Akiyama, Mitoshi
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.09.2012
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.23277

Cover

Loading…
More Information
Summary:Previous studies have reported that the signal attenuation of diffusion weighted magnetic resonance imaging for tumor tissues displays a non‐monoexponential biexponential decay, and the apparent diffusion coefficients (ADCs) can be divided into a fast and slow diffusion component by using a simple biexponential decay model. The purpose of this study is to examine the non‐monoexponential character of the diffusion weighted magnetic resonance imaging signal attenuations of breast cancers, estimate the fast and slow diffusion components, and compare them with the extra‐ and intracellular component information obtained from the pathological specimens. Twenty‐two subjects having breast cancers underwent diffusion weighted magnetic resonance imaging using six b‐values up to 3500 s/mm2 and the signal attenuations were analyzed using the biexponential function. The derived slow component fraction correlated with the cellular fraction and the ADCs converged to 0.2−0.3 × 10−3 mm2/s for the higher cellular fractions. The ADCs of the fast component ranged from 1.3 to 3.9 × 10−3 mm2/s and showed no correlation with the extracellular components. This result suggests that the main reason for the decreasing ADC of a breast tumor is the decreasing fraction of the fast component and the increasing fraction of the slow component having a low ADC rather than the decreasing ADC of the fast component by the restricted water diffusion in the reduced extracellular spaces. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Bibliography:istex:2FF6E9E124646466EDB135E769D16BD6D33C83DB
ark:/67375/WNG-SG6P0PW0-9
ArticleID:MRM23277
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.23277