Descriptors of Failed Extubation in Norwood Patients Using Physiologic Data Streaming

The objective of this study is to evaluate the utility of high-frequency physiologic data during the extubation process and other clinical variables for describing the physiologic profile of extubation failure in neonates with hypoplastic left heart syndrome (HLHS) post-Norwood procedure. This is a...

Full description

Saved in:
Bibliographic Details
Published inPediatric cardiology Vol. 44; no. 2; pp. 396 - 403
Main Authors Savorgnan, Fabio, Loomba, Rohit S., Flores, Saul, Rusin, Craig G., Zheng, Feng, Hassan, Adel M., Acosta, Sebastian
Format Journal Article
LanguageEnglish
Published New York Springer US 01.02.2023
Springer
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The objective of this study is to evaluate the utility of high-frequency physiologic data during the extubation process and other clinical variables for describing the physiologic profile of extubation failure in neonates with hypoplastic left heart syndrome (HLHS) post-Norwood procedure. This is a single-center, retrospective analysis. Extubation events were collected from January 2016 until July 2021. Extubation failure was defined as the need for re-intubation within 48 h of extubation. The data included streaming heart rate, respiratory rate, blood pressure, arterial oxygen saturation, and cerebral/renal near-infrared spectroscopy (NIRS). The most recent blood laboratory results before extubation were also included. These markers, demographics, clinical characteristics, and ventilatory settings were compared between successful and failed extubations. The analysis included 311 extubations. The extubation failure rate was 10%. According to univariable analyses, failed extubations were preceded by higher respiratory rates ( p  = 0.029), lower end-tidal CO 2 ( p  = 0.009), lower pH ( p  = 0.043), lower serum bicarbonate ( p  = 0.030), and lower partial pressure of O 2 ( p  = 0.022). In the first 10 min after extubation, the failed events were characterized by lower arterial ( p  = 0.028) and cerebral NIRS ( p  = 0.018) saturations. Failed events were associated with persistently lower values for cerebral NIRS 2 h post-extubation ( p  = 0.027). In multivariable analysis, vocal cord anomaly, cerebral NIRS at 10 min post-extubation, renal NIRS at pre-extubation and post-extubation, and end-tidal CO 2 at pre-extubation remained as significant co-variables. Oximetric indices before, in the 10 min immediately after, and 2 h after extubation and vocal cords paralysis are associated with failed extubation events in patients with parallel circulation.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0172-0643
1432-1971
DOI:10.1007/s00246-022-03084-8