Computer-based Insulin Infusion Protocol Improves Glycemia Control over Manual Protocol

Hyperglycemia worsens clinical outcomes in critically ill patients. Precise glycemia control using intravenous insulin improves outcomes. To determine if we could improve glycemia control over a previous paper-based, manual protocol, authors implemented, in a surgical intensive care unit (SICU), an...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American Medical Informatics Association : JAMIA Vol. 14; no. 3; pp. 278 - 287
Main Authors Boord, Jeffrey B., Sharifi, Mona, Greevy, Robert A., Griffin, Marie R., Lee, Vivian K., Webb, Ty A., May, Michael E., Waitman, Lemuel R., May, Addison K., Miller, Randolph A.
Format Journal Article
LanguageEnglish
Published England Elsevier Inc 01.05.2007
American Medical Informatics Association
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Hyperglycemia worsens clinical outcomes in critically ill patients. Precise glycemia control using intravenous insulin improves outcomes. To determine if we could improve glycemia control over a previous paper-based, manual protocol, authors implemented, in a surgical intensive care unit (SICU), an intravenous insulin protocol integrated into a care provider order entry (CPOE) system. Retrospective before-after study of consecutive adult patients admitted to a SICU during pre (manual protocol, 32 days) and post (computer-based protocol, 49 days) periods. Percentage of glucose readings in ideal range of 70–109 mg/dl, and minutes spent in ideal range of control during the first 5 days of SICU stay. The computer-based protocol reduced time from first glucose measurement to initiation of insulin protocol, improved the percentage of all SICU glucose readings in the ideal range, and improved control in patients on IV insulin for ≥24 hours. Hypoglycemia (<40 mg/dl) was rare in both groups. The CPOE-based intravenous insulin protocol improved glycemia control in SICU patients compared to a previous manual protocol, and reduced time to insulin therapy initiation. Integrating a computer-based insulin protocol into a CPOE system achieved efficient, safe, and effective glycemia control in SICU patients.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1067-5027
1527-974X
DOI:10.1197/jamia.M2292