Continuous Monitoring of Lactate Using Intravascular Microdialysis in High-Risk Cardiac Surgery: a Prospective Observational Study

Objective To assess the accuracy and applicability of a novel system, not requiring calibration, for continuous lactate monitoring with intravascular microdialysis in high-risk cardiac surgery. Design Single-center prospective observational study. Setting City Hospital #1 of Arkhangelsk, Russian Fed...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiothoracic and vascular anesthesia Vol. 31; no. 1; pp. 37 - 44
Main Authors Lenkin, Pavel I., MD, Smetkin, Alexey A., MD, Hussain, Ayyaz, MD, Lenkin, Andrey I., MD, Paromov, Konstantin V., MD, Ushakov, Alexey A., MD, Krygina, Maria M., MD, Kuzkov, Vsevolod V., MD, Kirov, Mikhail Y., MD, PhD
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.02.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective To assess the accuracy and applicability of a novel system, not requiring calibration, for continuous lactate monitoring with intravascular microdialysis in high-risk cardiac surgery. Design Single-center prospective observational study. Setting City Hospital #1 of Arkhangelsk, Russian Federation. Participants Twenty-one adult patients undergoing elective complex repair or replacement of two or more valves or combined valve and coronary artery cardiac surgery. Interventions After induction of anesthesia, in all patients a dedicated triple-lumen catheter functioning as a regular central venous catheter with integrated microdialysis function was inserted via the right jugular vein for continuous lactate monitoring using the intravascular microdialysis system. Measurements and Main Results Lactate values displayed by the microdialysis system were compared with the reference arterial blood gas (ABG) values. In total, 432 paired microdialysis-ABG lactate samples were obtained. After surgery, the concentration of lactate increased significantly, peaking at 8 hours (p<0.05). The lactate clearance within 8 hours after peak concentration was 50% (39%-63%). There was a significant correlation between Lactatecont and Lactatecont (rho = 0.92, p<0.0001). Bland–Altman analysis showed a bias (mean difference)±limits of agreement (±1.96 SD) of 0.09±1.1 mmol/L. In patients with postoperative complications, peak lactate concentration was significantly higher compared with those without complications: 6.75 (4.43-7.75) mmol/L, versus 4.20 (3.95-4.87) mmol/L (p = 0.002). Conclusions Lactate concentration increased significantly after high-risk cardiac surgery. The intravascular microdialysis technique for lactate measurement provided acceptable accuracy and can be used for continuous blood lactate monitoring in cardiac surgery.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:1053-0770
1532-8422
DOI:10.1053/j.jvca.2016.04.013