Non-contrast cardiac CT-based quantitative evaluation of epicardial and intra-thoracic fat in healthy, recently menopausal women: Reproducibility data from the Kronos Early Estrogen Prevention Study
Cardiac fat is emerging as an important parameter for cardiovascular risk stratification. Accurate and reproducible volumetric measurements can facilitate in the serial assessment of cardiac fat by computed tomography (CT). We assessed the intra- and inter-observer variability of cardiac fat volumet...
Saved in:
Published in | Journal of cardiovascular computed tomography Vol. 14; no. 1; pp. 55 - 59 |
---|---|
Main Authors | , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Elsevier Inc
01.01.2020
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Cardiac fat is emerging as an important parameter for cardiovascular risk stratification. Accurate and reproducible volumetric measurements can facilitate in the serial assessment of cardiac fat by computed tomography (CT). We assessed the intra- and inter-observer variability of cardiac fat volumetric measurements using a semi-automated CT software.
We used non-contrast coronary calcium CT scans to quantify epicardial and intra-thoracic fat volumes. Two expert readers analyzed baseline and follow up CT scans of 45 subjects by using a semi-automated CT software (QFAT 2.0, Cedars Sinai-Medical Center). Correlation and Bland-Altman analysis was performed for both intra- and inter-observer comparisons for each cardiac fat type.
The intra-observer correlation coefficients ranged between 0.86 to 0.99 and 0.87 to 0.99 for epicardial (median fat per reader (cm3) 20.9 to 25.7) and intra-thoracic (median fat per reader (cm3) 27.1 to 31.6) fat volumes respectively, with no significant differences between individual data points (all p > 0.38). The inter-observer correlation coefficient was 0.99 (p < 0.0001 for correlation) for both epicardial and intra-thoracic fat. By Bland-Altman analysis for epicardial fat measurements, mean difference of intra-observer was 0.90 cm3 with 95% confidence intervals (0.22,1.7) and −1.8 cm3 for inter-observer, with 95% CI (−2.9, −0.69). Bland-Altman plots for intra-thoracic fat measurements were similarly impressive for both inter- and intra-observer reads.
Our data showed that measuring epicardial and intra-thoracic fat volumes by CT using a semi-automated software has excellent intra-observer and inter-observer reliability. Cardiac fat volumes can be obtained easily and reproducibly from routine calcium scoring scans and may help in assessing cardiovascular risk.
URL: https://www.clinicaltrials.gov. Unique identifier: NCT00154180; Keywords: Epicardial fat volume; intra-thoracic fat volume; computed tomography; intra-observer; inter-observer. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1934-5925 1876-861X |
DOI: | 10.1016/j.jcct.2019.05.004 |