Ideation and assessment of a nitric oxide delivery system for spontaneously breathing subjects

There is an increasing interest in safely delivering high dose of inhaled nitric oxide (NO) as an antimicrobial and antiviral therapeutics for spontaneously breathing patients. A novel NO delivery system is described. We developed a gas delivery system that utilizes standard respiratory circuit conn...

Full description

Saved in:
Bibliographic Details
Published inNitric oxide Vol. 104-105; pp. 29 - 35
Main Authors Gianni, Stefano, Morais, Caio C.A., Larson, Grant, Pinciroli, Riccardo, Carroll, Ryan, Yu, Binglan, Zapol, Warren M., Berra, Lorenzo
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.11.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:There is an increasing interest in safely delivering high dose of inhaled nitric oxide (NO) as an antimicrobial and antiviral therapeutics for spontaneously breathing patients. A novel NO delivery system is described. We developed a gas delivery system that utilizes standard respiratory circuit connectors, a reservoir bag, and a scavenging chamber containing calcium hydroxide. The performance of the system was tested using a mechanical lung, assessing the NO concentration delivered at varying inspiratory flows. Safety was assessed in vitro and in vivo by measuring nitrogen dioxide (NO2) levels in the delivered NO gas. Lastly, we measured the inspired and expired NO and NO2 of this system in 5 healthy subjects during a 15-min administration of high dose NO (160 parts-per-million, ppm) using our delivery system. The system demonstrated stable delivery of prescribed NO levels at various inspiratory flow rates (0–50 L/min). The reservoir bag and a high flow of entering air minimized the oscillation of NO concentrations during inspiration on average 4.6 ppm for each 10 L/min increment in lung inspiratory flow. The calcium hydroxide scavenger reduced the inhaled NO2 concentration on average 0.9 ppm (95% CI -1.58, −0.22; p = .01). We performed 49 NO administrations of 160 ppm in 5 subjects. The average concentration of inspired NO was 164.8±10.74 ppm, with inspired NO2 levels of 0.7±0.13 ppm. The subjects did not experience any adverse events; transcutaneous methemoglobin concentrations increased from 1.05±0.58 to 2.26±0.47%. The system we developed to administer high-dose NO for inhalation is easy to build, reliable, was well tolerated in healthy subjects. •We conceived and tested a NO delivery system for spontaneously breathing subjects.•A scavenger containing calcium hydroxide reduces the inspired NO2 concentration.•A reservoir bag reduces variations of NO concentration during breathing.•In five healthy subjects breathing 164.8±10.74 ppm of NO, inspired NO2 was 0.7±0.13 ppm.•In a healthy subject breathing 153 ppm of NO, the exhaled NO2 was 0.03 ppm.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
These authors contributed equally to this work.
ISSN:1089-8603
1089-8611
1089-8611