Single Photon Emission Computed Tomography of Pulmonary Emboli and Venous Thrombi Using Anti-D-Dimer

Previous attempts to diagnose thromboemboli using radiolabeled antibodies and nuclear medicine imaging have been disappointing. We present the results of experiments with intravenous technetium-99m-labeled deimmunized antifibrin Fab' fragments to diagnose thromboemboli using single photon emiss...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of respiratory and critical care medicine Vol. 169; no. 9; pp. 987 - 993
Main Authors Morris, Timothy A, Marsh, James J, Chiles, Peter G, Konopka, Ronald G, Pedersen, Craig A, Schmidt, Peter F, Gerometta, Michael
Format Journal Article
LanguageEnglish
Published New York, NY Am Thoracic Soc 01.05.2004
American Lung Association
American Thoracic Society
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Previous attempts to diagnose thromboemboli using radiolabeled antibodies and nuclear medicine imaging have been disappointing. We present the results of experiments with intravenous technetium-99m-labeled deimmunized antifibrin Fab' fragments to diagnose thromboemboli using single photon emission computed tomography (SPECT), a highly sensitive scintigraphic imaging technique. Pulmonary emboli (PEs) and lower extremity deep vein thrombi (DVTs) were formed in five dogs, then technetium-99m-labeled Fab' ( approximately 400 mg, approximately 260 MBq) were injected via forelimb veins. Thoracic and lower extremity SPECT scans were performed at 2-hour intervals after antibody infusion to visualize the thromboemboli. Four hours after antibody infusion, all PEs and DVTs of mass 0.4 g or greater were clearly visualized on SPECT scans as 'hot spots' within the lungs and legs, respectively. PEs (0.48 +/- 0.09 g) were intensely radiolabeled, yielding clot/blood radioactivity ratios of 22.8 +/- 5.6. DVTs (0.45 +/- 0.31 g) also had high clot/blood ratios (11.7 +/- 2.6). Infusion of these radiolabeled antibody fragments, combined with SPECT, produces clear images of PEs and DVTs within a clinically feasible time frame. The technique reliably identified even peripheral thromboemboli of relatively small size, which are difficult to diagnose with currently available imaging techniques, and may enable imaging of PEs, DVTs, or both in the same patient.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1073-449X
1535-4970
DOI:10.1164/rccm.200306-735OC