Stenting of the Right Ventricular Outflow Tract in the High-Risk Infant With Cyanotic Teratology of Fallot

Neonatal tetralogy of Fallot (TOF) repair carries an increased risk of low birthweight or premature infants. Studies are investigating stents in the right ventricular outflow tract (RVOT) as an alternative to aortopulmonary shunts. The authors review their institutional experience with RVOT stenting...

Full description

Saved in:
Bibliographic Details
Published inPediatric cardiology Vol. 35; no. 3; pp. 423 - 430
Main Authors Castleberry, Chesney D., Gudausky, Todd M., Berger, Stuart, Tweddell, James S., Pelech, Andrew N.
Format Journal Article
LanguageEnglish
Published New York Springer US 01.03.2014
Springer
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Neonatal tetralogy of Fallot (TOF) repair carries an increased risk of low birthweight or premature infants. Studies are investigating stents in the right ventricular outflow tract (RVOT) as an alternative to aortopulmonary shunts. The authors review their institutional experience with RVOT stenting in the high-risk infant with TOF. Data on sequential patients who received RVOT stents were reviewed, with collection of their surgical, echocardiographic, and catheterization data. Size-matched control subjects were identified and outcomes compared. Six infants went to the catheterization lab for RVOT stenting from 2008 to 2010. Five of these patients had placement of an RVOT stent after balloon dilation. The median saturations were 71 % on 48 % fraction of inspired oxygen (FiO 2 ), with improvement to 94 % ( p  < 0.001) on 39 % FiO 2 24 h after stent placement. As shown by echocardiography, the diameter of the median right pulmonary artery (RPA) was 2.6 mm ( z -score, −3.3), and the diameter of the left pulmonary artery (LPA) was 2.0 mm ( z -score, −4.5). Repeat echocardiography before surgery showed a statistically significant increase in RPA and LPA size as well as a modified McGoon ratio ( p  < 0.05). Four of the five patients subsequently underwent TOF repair. No stent fractures occurred. One patient had repair 10 days after stent placement secondary to stent malposition and tricuspid valve injury. The authors’ experience with stents in the RVOT of TOF patients has yielded good results, with significant improvement in oxygen saturations. Patients had successful elective surgical repair and stent removal without longer cardiopulmonary bypass times or recognizable complications compared with shunted patients.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0172-0643
1432-1971
1432-1971
DOI:10.1007/s00246-013-0796-z