Analysis of 25 underivatized amino acids in human plasma using ion-pairing reversed-phase liquid chromatography/time-of-flight mass spectrometry

Amino acids in biological fluids have previously been shown to be detectable using liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) with perfluorinated acids as ion‐pairing agents. To date, these studies have used precursor mass, retention time and tandem mass spectrometry...

Full description

Saved in:
Bibliographic Details
Published inRapid communications in mass spectrometry Vol. 21; no. 16; pp. 2717 - 2726
Main Authors Armstrong, Michael, Jonscher, Karen, Reisdorph, Nichole A.
Format Journal Article
LanguageEnglish
Published Chichester, UK John Wiley & Sons, Ltd 30.08.2007
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Amino acids in biological fluids have previously been shown to be detectable using liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) with perfluorinated acids as ion‐pairing agents. To date, these studies have used precursor mass, retention time and tandem mass spectrometry (MS/MS) to identify and quantify amino acids. While this is a potentially powerful technique, we sought to adapt the method to time‐of‐flight (TOF)MS. A new application of a recently described liquid chromatographic separation method was coupled with TOFMS to employ accurate mass for qualitative identification; resulting in additional qualitative data not available with standard single quadrupole data. In the current study, we evaluated 25 physiological amino acids and one dipeptide that are routinely quantified in human plasma. Accuracy and precision of the method was evaluated by spiking human plasma with a mix of the 25 amino acids; in addition, the inclusion of a cation‐exchange cleanup step was evaluated. The calibration curves were linear over a range from 1.56 to 400 µM. The dynamic range was found to be within physiological levels for all amino acids analyzed. Accuracy and precision for most of the amino acids was between 80–120% spike recovery and <10% relative standard deviation (RSD). The LC/MS technique described in this study relies on mass accuracy and is suitable for the quantitation of free amino acids in plasma. Copyright © 2007 John Wiley & Sons, Ltd.
Bibliography:ark:/67375/WNG-1X2RW307-X
Colorado Clinical Nutrition Research Unit - No. NIH/NIDDK P30 DK048520-09
istex:0AE31DA22CB77932C383B7805C06A015B7041247
ArticleID:RCM3124
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0951-4198
1097-0231
DOI:10.1002/rcm.3124