In vitro degradation, hemolysis, and cytocompatibility of PEO/PLLA composite coating on biodegradable AZ31 alloy

Magnesium and its alloys have large potential as degradable and absorbable biomaterials because of their mechanical properties and biocompatibility. However, their corrosion resistance is usually inadequate especially in physiological environment, which limits their broad applications in biomedical...

Full description

Saved in:
Bibliographic Details
Published inJournal of biomedical materials research. Part B, Applied biomaterials Vol. 103; no. 2; pp. 342 - 354
Main Authors Wei, Zhongling, Tian, Peng, Liu, Xuanyong, Zhou, Bangxin
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.02.2015
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Magnesium and its alloys have large potential as degradable and absorbable biomaterials because of their mechanical properties and biocompatibility. However, their corrosion resistance is usually inadequate especially in physiological environment, which limits their broad applications in biomedical areas. In this work, plasma electrolytic oxidized/poly(l-lactide) (PEO/PLLA) composite coating was successfully fabricated on biodegradable AZ31 alloy by combing PEO process and sealing with PLLA. The microstructure, elemental composition, and phase composition of the PEO/PLLA composite coating were investigated. The in vitro degradation of the PEO/PLLA composite coating in simulated body fluid (SBF) was also systematically evaluated. The results revealed that the PEO/PLLA composite coating improved the corrosion resistance of AZ31 alloy significantly. The corrosion potential shifted from -1.663V to more positive position -1.317 V and the corrosion current density was reduced with six-order of magnitude. The Mg(2+) ions, hydrogen release, and pH value change of solution caused by degradation were all decreased significantly. Moreover, the PEO process played a critical role in sustaining the integrity of the implant in long-term service. The result of hemolysis test showed that the PEO/PLLA composite coating vested AZ31 alloy a low hemolysis ratio (0.806 ± 0.771)%, which is much lower than the safe value of 5% according to ISO 10993-4. For the cytocompatibility test, compared with bare AZ31 alloy and PEO coating, MC3T3-E1 cells showed much better adhesion and proliferation on the PEO/PLLA composite coating with nearly 4-fold increase of cells after 7-day cultivation, indicating that the PEO/PLLA composite coating has good biocompatibility for biomedical applications.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1552-4973
1552-4981
DOI:10.1002/jbm.b.33208