Intra and Inter-Device Reliabilities of the Instrumented Timed-Up and Go Test Using Smartphones in Young Adult Population
The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance re...
Saved in:
Published in | Sensors (Basel, Switzerland) Vol. 24; no. 9; p. 2918 |
---|---|
Main Authors | , , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Switzerland
MDPI AG
01.05.2024
|
Subjects | |
Online Access | Get full text |
ISSN | 1424-8220 1424-8220 |
DOI | 10.3390/s24092918 |
Cover
Abstract | The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants’ bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland–Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment. |
---|---|
AbstractList | The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants’ bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland–Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment. The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants' bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland-Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment.The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants' bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland-Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment. |
Audience | Academic |
Author | Belgamo, Anderson Cabral, André dos Santos Marques, Amélia Pasqual Costa e Silva, Anselmo de Athayde Souza, Givago Silva Pinto, Gustavo Henrique Lima Silva, Tacyla Jesus da Salomão, Railson Cruz Santos, Enzo Gabriel da Rocha dos Santos, Thâmela Thaís Santos Monteiro, Luis Carlos Pereira Costa, Wesley Thyago Alves da Gajewski, Jan Callegari, Bianca Kuliś, Szymon |
Author_xml | – sequence: 1 givenname: Thâmela Thaís Santos surname: dos Santos fullname: dos Santos, Thâmela Thaís Santos – sequence: 2 givenname: Amélia Pasqual surname: Marques fullname: Marques, Amélia Pasqual – sequence: 3 givenname: Luis Carlos Pereira orcidid: 0000-0002-0416-5182 surname: Monteiro fullname: Monteiro, Luis Carlos Pereira – sequence: 4 givenname: Enzo Gabriel da Rocha orcidid: 0000-0002-8927-4491 surname: Santos fullname: Santos, Enzo Gabriel da Rocha – sequence: 5 givenname: Gustavo Henrique Lima surname: Pinto fullname: Pinto, Gustavo Henrique Lima – sequence: 6 givenname: Anderson orcidid: 0000-0002-4302-7516 surname: Belgamo fullname: Belgamo, Anderson – sequence: 7 givenname: Anselmo de Athayde orcidid: 0000-0001-5265-619X surname: Costa e Silva fullname: Costa e Silva, Anselmo de Athayde – sequence: 8 givenname: André dos Santos orcidid: 0000-0002-3022-5847 surname: Cabral fullname: Cabral, André dos Santos – sequence: 9 givenname: Szymon orcidid: 0000-0002-0810-7086 surname: Kuliś fullname: Kuliś, Szymon – sequence: 10 givenname: Jan orcidid: 0000-0002-2146-6198 surname: Gajewski fullname: Gajewski, Jan – sequence: 11 givenname: Givago Silva orcidid: 0000-0002-4525-3971 surname: Souza fullname: Souza, Givago Silva – sequence: 12 givenname: Tacyla Jesus da surname: Silva fullname: Silva, Tacyla Jesus da – sequence: 13 givenname: Wesley Thyago Alves da surname: Costa fullname: Costa, Wesley Thyago Alves da – sequence: 14 givenname: Railson Cruz surname: Salomão fullname: Salomão, Railson Cruz – sequence: 15 givenname: Bianca orcidid: 0000-0001-9151-3896 surname: Callegari fullname: Callegari, Bianca |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/38733024$$D View this record in MEDLINE/PubMed |
BookMark | eNptkk1v1DAQhi1URD_gwB9AlrjAIa2_EtvHVaFlpUog2D1wihxnsvUqGwc7Qeq_77BbVqhCtuTR6JmZd2Z8Tk6GOAAhbzm7lNKyqywUs8Jy84KccSVUYYRgJ__Yp-Q85y1jQkppXpFTabSUTKgz8rAcpuSoG1qKFqTiE_wOHuh36INrQh-mAJnGjk73gESe0rwDBFu6Cjtoi_W4j72NdAV5ouschg39sXNpGu9RZKZhoD_jjM5FO_cT_RbHuXdTiMNr8rJzfYY3T-8FWd98Xl1_Ke6-3i6vF3eFV6WcCmtaVA2sVcxXqhRGVY0HJ7x3lZZMMS5Lp1vQJQjuNWcGb6lKZURndNPIC7I85G2j29ZjCijuoY4u1HtHTJsa1QbfQ62NsMpBqVmDxYVuPGe2sc4BZzg5gbk-HHKNKf6aseF6F7KHvncDxDnXkpXSVlYZiej7Z-g2zmnATveU4Br3gtTlgdo4rB-GLuI2PJ4WdsHjALuA_oW2sqysFAYD3j2lnRuc_7GfvxtF4OMB8CnmnKA7IpzVf35LffwtyF49Y32Y9stBFaH_T8Qjphe9Cw |
CitedBy_id | crossref_primary_10_3390_s24248096 |
Cites_doi | 10.3390/sports8070093 10.1111/j.1532-5415.1991.tb01616.x 10.1109/EMBC.2015.7319527 10.1186/1471-2342-8-16 10.1097/WNF.0000000000000371 10.3390/s23073426 10.3390/s22082935 10.7717/peerj.15627 10.3390/s22165957 10.3390/s18103310 10.1186/1475-925X-13-156 10.1109/MeMeA.2016.7533778 10.1109/BSN.2013.6575478 10.1088/0967-3334/32/12/009 10.1016/j.gaitpost.2012.02.006 10.1016/j.jstrokecerebrovasdis.2018.08.012 10.1016/j.gaitpost.2020.11.006 10.3390/electronics9030528 10.1088/0967-3334/36/9/1929 10.1016/j.gaitpost.2022.05.002 10.1080/09638288.2019.1682066 10.2307/2529310 10.1016/j.jns.2019.01.023 10.3390/s20174987 10.1016/j.regg.2017.02.009 10.1037/0033-2909.86.2.420 |
ContentType | Journal Article |
Copyright | COPYRIGHT 2024 MDPI AG 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. |
Copyright_xml | – notice: COPYRIGHT 2024 MDPI AG – notice: 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 3V. 7X7 7XB 88E 8FI 8FJ 8FK ABUWG AFKRA AZQEC BENPR CCPQU DWQXO FYUFA GHDGH K9. M0S M1P PHGZM PHGZT PIMPY PJZUB PKEHL PPXIY PQEST PQQKQ PQUKI PRINS 7X8 DOA |
DOI | 10.3390/s24092918 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed ProQuest Central (Corporate) Health & Medical Collection ProQuest Central (purchase pre-March 2016) Medical Database (Alumni Edition) Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central Essentials ProQuest Central ProQuest One Community College ProQuest Central Korea Health Research Premium Collection Health Research Premium Collection (Alumni) ProQuest Health & Medical Complete (Alumni) ProQuest Health & Medical Collection Medical Database ProQuest Central Premium ProQuest One Academic (New) ProQuest Publicly Available Content ProQuest Health & Medical Research Collection ProQuest One Academic Middle East (New) ProQuest One Health & Nursing ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China MEDLINE - Academic DOAJ Directory of Open Access Journals |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Publicly Available Content Database ProQuest One Academic Middle East (New) ProQuest Central Essentials ProQuest Health & Medical Complete (Alumni) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest One Health & Nursing ProQuest Central China ProQuest Central ProQuest Health & Medical Research Collection Health Research Premium Collection Health and Medicine Complete (Alumni Edition) ProQuest Central Korea Health & Medical Research Collection ProQuest Central (New) ProQuest Medical Library (Alumni) ProQuest One Academic Eastern Edition ProQuest Hospital Collection Health Research Premium Collection (Alumni) ProQuest Hospital Collection (Alumni) ProQuest Health & Medical Complete ProQuest Medical Library ProQuest One Academic UKI Edition ProQuest One Academic ProQuest One Academic (New) ProQuest Central (Alumni) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE Publicly Available Content Database CrossRef |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 3 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database – sequence: 4 dbid: BENPR name: ProQuest Central url: https://www.proquest.com/central sourceTypes: Aggregation Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 1424-8220 |
ExternalDocumentID | oai_doaj_org_article_78294ae570bc4527bc109b9aae103332 A793569328 38733024 10_3390_s24092918 |
Genre | Journal Article |
GeographicLocations | Brazil |
GeographicLocations_xml | – name: Brazil |
GrantInformation_xml | – fundername: National Council for Scientific and Technological Development grantid: #102167/2022-2 – fundername: National Council for Scientific and Technological Development grantid: #309936/2022-5 |
GroupedDBID | --- 123 2WC 53G 5VS 7X7 88E 8FE 8FG 8FI 8FJ AADQD AAHBH AAYXX ABDBF ABUWG ACUHS ADBBV ADMLS AENEX AFKRA AFZYC ALIPV ALMA_UNASSIGNED_HOLDINGS BENPR BPHCQ BVXVI CCPQU CITATION CS3 D1I DU5 E3Z EBD ESX F5P FYUFA GROUPED_DOAJ GX1 HH5 HMCUK HYE IAO ITC KQ8 L6V M1P M48 MODMG M~E OK1 OVT P2P P62 PHGZM PHGZT PIMPY PQQKQ PROAC PSQYO RNS RPM TUS UKHRP XSB ~8M 3V. ABJCF ARAPS CGR CUY CVF ECM EIF HCIFZ KB. M7S NPM PDBOC PMFND 7XB 8FK AZQEC DWQXO K9. PJZUB PKEHL PPXIY PQEST PQUKI PRINS 7X8 PUEGO |
ID | FETCH-LOGICAL-c453t-98d233e0d40c6452846bcea2cca673040135a7de75e21c7108108545482f87bb3 |
IEDL.DBID | 8FG |
ISSN | 1424-8220 |
IngestDate | Wed Aug 27 01:27:08 EDT 2025 Fri Sep 05 09:05:26 EDT 2025 Fri Jul 25 22:55:51 EDT 2025 Tue Jun 10 21:07:36 EDT 2025 Wed Feb 19 02:04:55 EST 2025 Tue Jul 01 03:50:57 EDT 2025 Thu Apr 24 23:12:39 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 9 |
Keywords | biomechanical phenomena research instrument evaluation smartphone test reproducibility timed-up and go test program evaluation |
Language | English |
License | https://creativecommons.org/licenses/by/4.0 |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c453t-98d233e0d40c6452846bcea2cca673040135a7de75e21c7108108545482f87bb3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ORCID | 0000-0002-0810-7086 0000-0002-4525-3971 0000-0002-4302-7516 0000-0001-5265-619X 0000-0002-8927-4491 0000-0002-3022-5847 0000-0002-0416-5182 0000-0001-9151-3896 0000-0002-2146-6198 |
OpenAccessLink | https://www.proquest.com/docview/3053217220?pq-origsite=%requestingapplication% |
PMID | 38733024 |
PQID | 3053217220 |
PQPubID | 2032333 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_78294ae570bc4527bc109b9aae103332 proquest_miscellaneous_3053969483 proquest_journals_3053217220 gale_infotracacademiconefile_A793569328 pubmed_primary_38733024 crossref_primary_10_3390_s24092918 crossref_citationtrail_10_3390_s24092918 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2024-05-01 |
PublicationDateYYYYMMDD | 2024-05-01 |
PublicationDate_xml | – month: 05 year: 2024 text: 2024-05-01 day: 01 |
PublicationDecade | 2020 |
PublicationPlace | Switzerland |
PublicationPlace_xml | – name: Switzerland – name: Basel |
PublicationTitle | Sensors (Basel, Switzerland) |
PublicationTitleAlternate | Sensors (Basel) |
PublicationYear | 2024 |
Publisher | MDPI AG |
Publisher_xml | – name: MDPI AG |
References | (ref_9) 2017; 52 (ref_12) 2015; 36 Christopher (ref_2) 2021; 43 Mellone (ref_6) 2012; 36 (ref_8) 2018; 27 Duarte (ref_18) 2022; 96 ref_14 ref_13 ref_11 ref_10 Landis (ref_24) 1977; 33 ref_19 ref_17 Yahalom (ref_15) 2020; 43 (ref_20) 2021; 84 Ishikawa (ref_16) 2019; 398 Duarte (ref_28) 2023; 11 ref_22 Weiss (ref_4) 2011; 32 ref_21 Yahalom (ref_25) 2018; 10 Shrout (ref_23) 1979; 86 ref_3 Podsiadlo (ref_1) 1991; 39 ref_27 ref_26 ref_5 ref_7 |
References_xml | – ident: ref_21 doi: 10.3390/sports8070093 – volume: 10 start-page: 689 year: 2018 ident: ref_25 article-title: AppTUG-A Smartphone Application of Instrumented “Timed up and Go” for Neurological Disorders publication-title: EC Neurol. – volume: 39 start-page: 142 year: 1991 ident: ref_1 article-title: The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons publication-title: J. Am. Geriatr. Soc. doi: 10.1111/j.1532-5415.1991.tb01616.x – ident: ref_11 doi: 10.1109/EMBC.2015.7319527 – ident: ref_22 doi: 10.1186/1471-2342-8-16 – volume: 43 start-page: 1 year: 2020 ident: ref_15 article-title: Psychiatric Patients on Neuroleptics: Evaluation of Parkinsonism and Quantified Assessment of Gait publication-title: Clin. Neuropharmacol. doi: 10.1097/WNF.0000000000000371 – ident: ref_5 doi: 10.3390/s23073426 – ident: ref_14 – ident: ref_19 doi: 10.3390/s22082935 – volume: 11 start-page: e15627 year: 2023 ident: ref_28 article-title: Comparison of Inertial Records during Anticipatory Postural Adjustments Obtained with Devices of Different Masses publication-title: PeerJ doi: 10.7717/peerj.15627 – ident: ref_27 doi: 10.3390/s22165957 – ident: ref_26 doi: 10.3390/s18103310 – ident: ref_7 doi: 10.1186/1475-925X-13-156 – ident: ref_10 doi: 10.1109/MeMeA.2016.7533778 – ident: ref_13 doi: 10.1109/BSN.2013.6575478 – volume: 32 start-page: 2003 year: 2011 ident: ref_4 article-title: An Instrumented Timed up and Go: The Added Value of an Accelerometer for Identifying Fall Risk in Idiopathic Fallers publication-title: Physiol. Meas. doi: 10.1088/0967-3334/32/12/009 – volume: 36 start-page: 163 year: 2012 ident: ref_6 article-title: Validity of a Smartphone-Based Instrumented Timed up and Go publication-title: Gait Posture doi: 10.1016/j.gaitpost.2012.02.006 – volume: 27 start-page: 3555 year: 2018 ident: ref_8 article-title: Using Smartphones to Collect Quantitative Data on Lower Limb Functionality in People Who Have Suffered a Stroke publication-title: J. Stroke Cerebrovasc. Dis. doi: 10.1016/j.jstrokecerebrovasdis.2018.08.012 – volume: 84 start-page: 8 year: 2021 ident: ref_20 article-title: The Timed up & Go Test Sit-to-Stand Transition: Which Signals Measured by Inertial Sensors Are a Viable Route for Continuous Analysis? publication-title: Gait Posture doi: 10.1016/j.gaitpost.2020.11.006 – ident: ref_3 doi: 10.3390/electronics9030528 – volume: 36 start-page: 1929 year: 2015 ident: ref_12 article-title: Clinical Frailty Syndrome Assessment Using Inertial Sensors Embedded in Smartphones publication-title: Physiol. Meas. doi: 10.1088/0967-3334/36/9/1929 – volume: 96 start-page: 9 year: 2022 ident: ref_18 article-title: Validity and Reliability of a Smartphone-Based Assessment for Anticipatory and Compensatory Postural Adjustments during Predictable Perturbations publication-title: Gait Posture doi: 10.1016/j.gaitpost.2022.05.002 – volume: 43 start-page: 1799 year: 2021 ident: ref_2 article-title: The Reliability and Validity of the Timed up and Go as a Clinical Tool in Individuals with and without Disabilities across a Lifespan: A Systematic Review: Psychometric Properties of the Timed Up and Go publication-title: Disabil. Rehabil. doi: 10.1080/09638288.2019.1682066 – volume: 33 start-page: 159 year: 1977 ident: ref_24 article-title: The Measurement of Observer Agreement for Categorical Data publication-title: Biometrics doi: 10.2307/2529310 – volume: 398 start-page: 45 year: 2019 ident: ref_16 article-title: Gait Analysis in a Component Timed-up-and-Go Test Using a Smartphone Application publication-title: J. Neurol. Sci. doi: 10.1016/j.jns.2019.01.023 – ident: ref_17 doi: 10.3390/s20174987 – volume: 52 start-page: 249 year: 2017 ident: ref_9 article-title: Reproducibilidad de Los Tiempos de Ejecución de La Prueba de Timed up and Go, Medidos Con Acelerómetros de Smartphones En Personas Mayores Residentes En La Comunidad publication-title: Rev. Esp. Geriatr. Gerontol. doi: 10.1016/j.regg.2017.02.009 – volume: 86 start-page: 420 year: 1979 ident: ref_23 article-title: Intraclass Correlations: Uses in Assessing Rater Reliability publication-title: Psychol. Bull. doi: 10.1037/0033-2909.86.2.420 |
SSID | ssj0023338 |
Score | 2.4222343 |
Snippet | The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test... |
SourceID | doaj proquest gale pubmed crossref |
SourceType | Open Website Aggregation Database Index Database Enrichment Source |
StartPage | 2918 |
SubjectTerms | Accidental Falls - prevention & control Adult Analysis biomechanical phenomena Body mass index Bone surgery Experiments Female Frailty Gait Humans Male Medical personnel Mobility Older people Professional ethics program evaluation Reproducibility of Results research instrument evaluation Sensors Smart phones Smartphone Smartphones Teenagers test reproducibility timed-up and go test Validity Young Adult Young adults Youth |
SummonAdditionalLinks | – databaseName: DOAJ Directory of Open Access Journals dbid: DOA link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1La9wwEBYlp_YQ0mecpkEpgfYiorUk2zpuk-ZRaCg0C7kJydZCIPEuJDn03_cbyWuWNpBLTgu2vJbnofnGHn3D2EGMiII-RAFsIYXuYi18Z5Xw1ttqHow3ivY7_7yozmb6x5W5Wmv1RTVhmR44C-4QEcxqH00tQ6tNWYd2Im2w3seJVEql1VdauUqmhlQLZ5rMI6SQ1B_eIW4BB1Bnj7Xok0j6_1-K_wGYKdCcbLHNASHyaZ7Za_Yi9m_YqzXewLfszzm9kuW-73h6oyeOIzk8p_rizLuN_Jcv5hzojp8njtjEvdlx2vHRidkyXXu64JeYCU9lA_z3LYRBleq49LrnaRngU6Ln4L_GLl_v2Ozk--XRmRh6KAhIS90L23QQRpSdli19wwTcCG30JRRXwbkpuzK-hopMLCct4EZD2xE08phy3tQhqPdso8edtxmPCP220UGFYHTp8dN0tfUtfH7u4dsF-7qSrWsHgnHqc3HjkGiQGtyohoJ9HocuM6vGY4O-kYLGAUSEnQ7APNxgHu4p8yjYF1KvI3fFZFo_7DrAIxHxlZtifTIVQCxut7uyADf48Z1T1DgDGK-UBdsfT8MD6bOK7-PiIY-xldWNKtiHbDnjnFVTKwUYtPMcz_KRvSzxX7nccpdtwHjiJ0Ci-7CXrP8v3nQGww priority: 102 providerName: Directory of Open Access Journals – databaseName: Scholars Portal Journals: Open Access dbid: M48 link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1Lb9QwEB6VcoED4k2gIIOQ4GLI-pHEB4SWR2mRipDoSr1ZduJFSCVb2iLRf883TjaiUHGKlEwSxzPj-Sa2vyF6mhKiYIhJAluU0nSplqFzWgYXXLWMNljN-533PlU7C_PxwB5s0LrG5tiBJxemdlxPanF8-OLXj7PXcPhXnHEiZX95gqiEKD9rLtFlBKSKc7A9M00mKI00bCAVOi9-LhRlxv5_x-W_0GaOOtvX6doIF8V80O8N2kj9Tbr6B4ngLTrb5f-zIvSdyL_35LvE3i94sfFAwo1kWKyWAlBP7GbC2EzE2Qne_tHJxVG-98NK7KMlIq8hEF--w6R42Tpu_daLPCaIOXN1iM9Tya_btNh-v_92R44FFWRrrD6VrunQGansTNnyhCawR2xTUNBiBU_nVMuGGvqySc1aYI-G9yYYJDVq2dQx6ju02ePN90gk4ADXmKhjtEYFHJqudqHFALAMcPSCnq_71rcj2zgXvTj0yDpYDX5SQ0FPJtGjgWLjIqE3rKBJgFmx84nV8Vc_OpkH2nEmJFuXER-s6tjOShddCGlWwghUQc9YvZ6tCY1pw7gFAZ_ELFh-jsHKVkC0eN3W2gL82ia95ioaAHyqLOjxdBnuyHMsoU-rn4OMq5xpdEF3B8uZ2qybWmtgovv_f_gDuqIgNayq3KJNmEV6CORzGh9lu_4NxLgAaw priority: 102 providerName: Scholars Portal |
Title | Intra and Inter-Device Reliabilities of the Instrumented Timed-Up and Go Test Using Smartphones in Young Adult Population |
URI | https://www.ncbi.nlm.nih.gov/pubmed/38733024 https://www.proquest.com/docview/3053217220 https://www.proquest.com/docview/3053969483 https://doaj.org/article/78294ae570bc4527bc109b9aae103332 |
Volume | 24 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1Nb9QwEB3R9gIHxDeBsjIICS5Ws7GdxCe0hW5bpFYVdKW9RXbiRUiQLGw58O9542RDBYjLRto4iZOZ8byxx2-IXoYAL-h8kMAWqdRNKKRrrJLOOpuvvHFG8X7ns_P8ZKHfL81ymHDbDGmV2zExDtRNV_Mc-YHiEgbwtln6Zv1NctUoXl0dSmjs0N4Unob1vJwfjwGXQvzVswkphPYHG3gvoAGu73HNB0Wq_r8H5D9gZnQ38zt0e8CJYtYL9i7dCO09unWNPfA-_TzliVnh2kbEeT35LrDZC84y7tm3EQWLbiWA8cRpZIqNDJyN4H0fjVys47XHnbhET0RMHhAfv0KXOF8dl35uRRwMxIxJOsTFWOvrAS3mR5dvT-RQSUHW2qgracsGHyOkjU5rXskE6PB1cBnEl8PEOcYyroCgTMimNUBHyZsSNKKZbFUW3quHtNviyY9JBAAAW2qvvDc6cziUTWFdDctfOVh4Qq-337aqB5pxrnbxpUK4wWKoRjEk9GJsuu65Nf7V6JAFNDZgOuz4R_f9UzVYVwWYY7ULpkg9XjgrfD1NrbfOhWkKJcgSesXirdho0ZnaDXsP8EpMf1XNMEqZHFAWj9vfakA1WPOm-q17CT0fT8MOeXHFtaH70bexudWlSuhRrzljn1VZKAUw9OT_N39KNzO06tMp92kXahGeAfJc-QntFMtiErV7QnuHR-cXHyZx-gC_Z7r8BRgHAzE |
linkProvider | ProQuest |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwELZKOQAHxJtAAYNAcImatZ2HDwgtlLJLH0JiV9qbaydehATJwhah_il-I984j1aAuPUUKbETO_488409nmHsqffQgtb5GNwiiVXl89hWWsZWW50tXWpTSeedDw6zyVy9X6SLDfarPwtDbpW9TAyCumpKWiPflpTCANpWJK9W32LKGkW7q30KjRYWe_7kJ0y29cvpDsb3mRC7b2dvJnGXVSAuVSqPY11UQkqfVCopaVcPCtiV3gp0JQPcyd5IbY5Gp16MSijgghz0FZi9WBa5cxLvvcAuKloZx_zJF6cGnoS910YvklIn22toS7APyidyRueF1AB_K4A_aG1Qb7vX2NWOl_JxC6TrbMPXN9iVM9EKb7KTKS0Ec1tXPKwjxjuexAwnr-Y22jesbt4sOTgln4bItCHiZ8XpnEkVz1eh7ruGz9ASHpwV-MevwC75x6Pq55oH4cPHFBSEfxhyi91i83P5x7fZZo0v32Xcg3DoQjnpXKqExaWocm1LSJqlhUSJ2Iv-35qyC2tO2TW-GJg3NAxmGIaIPRmKrtpYHv8q9JoGaChA4bfDjeb7J9PNZgNapZX1aZ44dFjkrhwl2mlr_SgBCETEntPwGhISaExpu7MO6BKF2zJjSMU0A3XG57Z6BJhOeqzNKdYj9nh4jHlPmzm29s2PtozOtCpkxO60yBnaLItcSpCve_9_-SN2aTI72Df708O9--yyQI3WlXOLbQIi_gHo1rF7GDDO2dF5T6rfnzE5hg |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwELZKkRAcEG8WChgEgou1WTsvHxBaWJYuhaoSXWlvxk4chATJwhah_jV-Hd84j1aAuPUUKbETOx5_8409nmHssffQgtZ5AW4Ribj0mbClVsJqq9PKJTZRdN75_X66u4zfrpLVFvvVn4Uht8oeEwNQl01Ba-RjRSkMoG1lNK46t4iD2fzF-pugDFK009qn02hFZM8f_4T5tnm-mGGsn0g5f334ald0GQZEESfqSOi8lEr5qIyjgnb4oIxd4a1Et1KIPtkeic3QgcTLSQFlnJOzfgyWL6s8c07hvefY-UyBVWEuZasTY0_B9msjGSmlo_EGmhNMhHKLnNJ_IU3A38rgD4obVN38CrvccVQ-bYXqKtvy9TV26VTkwuvseEGLwtzWJQ9rimLmCXI4eTi3kb9hgfOm4uCXfBGi1IbonyWnMyelWK5D3TcNP0RLeHBc4B--Qo7JVx5VP9c8ABGfUoAQfjDkGbvBlmfyj2-y7Rpfvs24B_nQeeyUc0ksLS55mWlbAHUqC3QZsWf9vzVFF-KcMm18MTB1aBjMMAwj9mgoum7jevyr0EsaoKEAheION5rvn0w3sw0olo6tT7LIocMyc8Uk0k5b6ycRhECO2FMaXkOAgcYUtjv3gC5R6C0zBUImKWg0PrfTS4DpkGRjTuR-xB4Oj4EBtLFja9_8aMvoVMe5GrFbreQMbVZ5phSI2J3_v_wBu4DpZN4t9vfusosSFVqvzh22DQnx98C8jtz9IOKcfTzrOfUbcxc9xQ |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Intra+and+Inter-Device+Reliabilities+of+the+Instrumented+Timed-Up+and+Go+Test+Using+Smartphones+in+Young+Adult+Population&rft.jtitle=Sensors+%28Basel%2C+Switzerland%29&rft.au=Th%C3%A2mela+Tha%C3%ADs+Santos+dos+Santos&rft.au=Am%C3%A9lia+Pasqual+Marques&rft.au=Pereira+Monteiro%2C+Luis+Carlos&rft.au=Enzo+Gabriel+da+Rocha+Santos&rft.date=2024-05-01&rft.pub=MDPI+AG&rft.eissn=1424-8220&rft.volume=24&rft.issue=9&rft.spage=2918&rft_id=info:doi/10.3390%2Fs24092918&rft.externalDBID=HAS_PDF_LINK |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1424-8220&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1424-8220&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1424-8220&client=summon |