Haemodynamics and cardiac function during robotic-assisted laparoscopic prostatectomy in steep Trendelenburg position

Background Robotic‐assisted laparoscopic prostatectomy (RALP) is usually performed in steep Trendelenburg position, which can be associated with cardiac impairment due to positioning and capnoperitoneum. This study investigated haemodynamic consequences and cardiac function in this type of surgery a...

Full description

Saved in:
Bibliographic Details
Published inThe international journal of medical robotics + computer assisted surgery Vol. 7; no. 4; pp. 408 - 413
Main Authors Haas, Sebastian, Haese, Alexander, Goetz, Alwin E., Kubitz, Jens C.
Format Journal Article
LanguageEnglish
Published Chichester, UK John Wiley & Sons, Ltd 01.12.2011
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Robotic‐assisted laparoscopic prostatectomy (RALP) is usually performed in steep Trendelenburg position, which can be associated with cardiac impairment due to positioning and capnoperitoneum. This study investigated haemodynamic consequences and cardiac function in this type of surgery and evaluated the hypothesis that steep Trendelenburg position and capnoperitoneum results in haemodynamic and ventricular impairment. Methods 10 patients (ASA I‐III) scheduled for RALP in steep Trendelenburg position with capnoperitoneum were prospectively studied. Heart rate (HR), mean arterial pressure (MAP) and central venous pressure (CVP) were recorded. Stroke volume variation (SVV) and cardiac output (CO) were measured using pulse‐contour analysis. Further, cardiac function was assessed using trans‐oesophageal echocardiography before positioning (T1) and 10 min (T2) and 60 min (T3) after implementation of steep Trendelenburg position and capnoperitoneum. Results HR did not change statistically. MAP (T1, 69.7 ± 1.55; T2, 82.9 ± 3.05; T3, 79.4 ± 2.18 mmHg), CVP (T1, 7.7 ± 1.3; T2, 17.3 ± 2.01; T3, 16.9 ± 1.66 mmHg) and CO (T1, 4.0 ± 0.15; T2, 4.9 ± 0.26; T3, 4.9 ± 0.36 l/min) increased significantly at T2 and T3. Echocardiography showed no deterioration of left or right ventricular function. In one patient with pre‐existing mitral valve insufficiency (I°) an aggravation of the insufficiency (III°) was observed. No other valve dysfunctions were observed. Conclusions The steep Trendelenburg position may improve haemodynamic function and does not deteriorate left or right ventricular function during RALP. However, mitral valve insufficiency may be aggravated by positioning and capnoperitoneum. Copyright © 2011 John Wiley & Sons, Ltd.
Bibliography:ark:/67375/WNG-NJNX26DK-4
ArticleID:RCS410
istex:38E8BB309C5AD941F5BED09F3FFD1C9018C42E89
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:1478-5951
1478-596X
1478-596X
DOI:10.1002/rcs.410