Post-landing major element quantification using SuperCam laser induced breakdown spectroscopy

The SuperCam instrument on the Perseverance Mars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and...

Full description

Saved in:
Bibliographic Details
Published inSpectrochimica acta. Part B: Atomic spectroscopy Vol. 188; p. 106347
Main Authors Anderson, Ryan B., Forni, Olivier, Cousin, Agnes, Wiens, Roger C., Clegg, Samuel M., Frydenvang, Jens, Gabriel, Travis S.J., Ollila, Ann, Schröder, Susanne, Beyssac, Olivier, Gibbons, Erin, Vogt, David S., Clavé, Elise, Manrique, Jose-Antonio, Legett, Carey, Pilleri, Paolo, Newell, Raymond T., Sarrao, Joseph, Maurice, Sylvestre, Arana, Gorka, Benzerara, Karim, Bernardi, Pernelle, Bernard, Sylvain, Bousquet, Bruno, Brown, Adrian J., Alvarez-Llamas, César, Chide, Baptiste, Cloutis, Edward, Comellas, Jade, Connell, Stephanie, Dehouck, Erwin, Delapp, Dorothea M., Essunfeld, Ari, Fabre, Cecile, Fouchet, Thierry, Garcia-Florentino, Cristina, García-Gómez, Laura, Gasda, Patrick, Gasnault, Olivier, Hausrath, Elisabeth M., Lanza, Nina L., Laserna, Javier, Lasue, Jeremie, Lopez, Guillermo, Madariaga, Juan Manuel, Mandon, Lucia, Mangold, Nicolas, Meslin, Pierre-Yves, Nelson, Anthony E., Newsom, Horton, Reyes-Newell, Adriana L., Robinson, Scott, Rull, Fernando, Sharma, Shiv, Simon, Justin I., Sobron, Pablo, Fernandez, Imanol Torre, Udry, Arya, Venhaus, Dawn, McLennan, Scott M., Morris, Richard V., Ehlmann, Bethany
Format Journal Article
LanguageEnglish
Published Johnson Space Center Elsevier B.V 01.02.2022
Science Direct
Elsevier BV
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The SuperCam instrument on the Perseverance Mars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions and spectra are normalized to minimize signal fluctuations and effects of target distance. In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositions of diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g., silicates, sulfates, carbonates, oxides), more unusual compositions (e.g., Mn ore and sodalite), and replicates of the sintered SuperCam calibration targets (SCCTs) onboard the rover. For each major element (SiO2, TiO2, Al2O3, FeOT, MgO, CaO, Na2O, K2O), the database was subdivided into five “folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining four folds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3 m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS. [Display omitted] •We quantify the following oxides: SiO2, TiO2, Al2O3, FeOT, MgO, CaO, Na2O, K2O.•Multivariate regression models were trained on a diverse suite of spectra.•Of the algorithms considered, ensemble methods performed well but had limitations.•We evaluated models based on laboratory and Mars results.•Work is ongoing to improve major element results and quantify additional elements.
Bibliography:Johnson Space Center
JSC
National Aeronautics and Space Administration (NASA)
USDOE
LA-UR-21-31442
89233218CNA000001
ISSN:0584-8547
1873-3565
DOI:10.1016/j.sab.2021.106347