Impact of Nationwide COVID-19 Lockdowns on the Implantation Rate of Cardiac Implantable Electronic Devices
The COVID-19 pandemic resulted in a significant decrease in the number of hospital admissions for severe emergent cardiovascular diseases during lockdowns worldwide. This study aimed to determine the impact of both the first and the second Danish nationwide lockdown on the implantation rate of cardi...
Saved in:
Published in | Heart, lung & circulation Vol. 32; no. 3; pp. 364 - 372 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Australia
Elsevier B.V
01.03.2023
The Author(s). Published by Elsevier B.V. on behalf of Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ) |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The COVID-19 pandemic resulted in a significant decrease in the number of hospital admissions for severe emergent cardiovascular diseases during lockdowns worldwide. This study aimed to determine the impact of both the first and the second Danish nationwide lockdown on the implantation rate of cardiac implantable electronic devices (CIEDs).
We retrospectively analysed the number of CIED implantations performed in Denmark and stratified them into 3-week intervals.
The total number of de novo CIED implantations decreased during the first lockdown by 15.5% and during the second by 5.1%. Comparing each 3-week interval using rate ratios, a significant decrease in the daily rates of the total number of de novo and replacement CIEDs (0.82, 95% CI [0.70, 0.96]), de novo CIEDs only (0.82, 95% CI [0.69, 0.98]), and non-acute pacemaker implantations (0.80, 95% CI [0.63, 0.99]) was observed during the first interval of the first lockdown. During the second lockdown (third interval), a significant decrease was seen in the daily rates of de novo CIEDs (0.73, 95% CI [0.55, 0.97]), and of pacemakers in total during both the second (0.78, 95% CI [0.62, 0.97]) and the third (0.60, 95% CI [0.42, 0.85]) intervals. Additionally, the daily rates of acute pacemaker implantation decreased during the second interval (0.47, 95% CI [0.27, 0.79]) and of non-acute implantation during the third interval (0.57, 95% CI [0.38, 0.84]). A significant increase was observed in the number of replacement procedures during the first interval of the second lockdown (1.70, 95% CI [1.04, 2.85]).
Our study found only modest changes in CIED implantations in Denmark during two national lockdowns. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1443-9506 1444-2892 |
DOI: | 10.1016/j.hlc.2022.10.013 |