Simultaneous detection of feline parvovirus and feline bocavirus using SYBR Green I-based duplex real-time polymerase chain reaction

Since both feline parvovirus (FPV) and feline bocavirus (FBoV) can cause diarrhea in cats, it is difficult to distinguish them clinically. This study aimed to develop a SYBR Green I-based duplex real-time polymerase chain reaction (PCR) assay for distinguishing FPV and FBoV-1 on the basis of the mel...

Full description

Saved in:
Bibliographic Details
Published in3 Biotech Vol. 11; no. 9; p. 400
Main Authors Wang, Yong, Pan, Yang, Wu, Junhuang, Tong, Xinxin, Sun, Jianfei, Xu, Fazhi, Cheng, Bangzhao, Li, Yongdong
Format Journal Article
LanguageEnglish
Published Cham Springer International Publishing 01.09.2021
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Since both feline parvovirus (FPV) and feline bocavirus (FBoV) can cause diarrhea in cats, it is difficult to distinguish them clinically. This study aimed to develop a SYBR Green I-based duplex real-time polymerase chain reaction (PCR) assay for distinguishing FPV and FBoV-1 on the basis of the melting temperature of the PCR product. A total of 132 fecal samples from different domestic and feral cats were collected, and the results of SYBR Green I-based duplex real-time PCR assay were compared with those of the traditional PCR assay for a comprehensive evaluation. The melting temperatures were found to be 86 °C and 77.5 °C for FBoV-1 and FPV, respectively, and no specific melting peaks for other non-targeted feline viruses were observed. The data obtained from this assay had a good linear relationship; the detection limits of FPV and FBoV-1 were 2.907 × 10 1 copies/μL and 3.836 × 10 1 copies/μL, respectively. In addition, the experiment exhibited high reproducibility. The positive detection rates of the SYBR Green I-based duplex real-time PCR assay for FPV and FBoV-1 were 16.67% (22/132) and 6.82% (9/132), respectively, and the positive detection rate for co-infection with FPV and FBoV-1 was 3.03% (4/132). This result was much more sensitive than that of the traditional PCR method. Thus, the developed SYBR Green I-based assay is a sensitive, rapid, specific, and reliable method for the clinical diagnosis of FPV and FBoV-1 and can provide technical support for the simultaneous detection of co-infection with these viruses in the future.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2190-572X
2190-5738
DOI:10.1007/s13205-021-02947-w