Silicone breast implant rupture: pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound

The objective of this study was to evaluate the relative efficacies of magnetic resonance (MR) imaging, ultrasonography, and mammography in implant rupture detection and to illustrate pitfalls in MR image interpretation. Thirty patients referred by plastic surgeons with suspected breast implant rupt...

Full description

Saved in:
Bibliographic Details
Published inPlastic and reconstructive surgery (1963) Vol. 104; no. 7; p. 2054
Main Authors Ikeda, D M, Borofsky, H B, Herfkens, R J, Sawyer-Glover, A M, Birdwell, R L, Glover, G H
Format Journal Article
LanguageEnglish
Published United States 01.12.1999
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:The objective of this study was to evaluate the relative efficacies of magnetic resonance (MR) imaging, ultrasonography, and mammography in implant rupture detection and to illustrate pitfalls in MR image interpretation. Thirty patients referred by plastic surgeons with suspected breast implant rupture were prospectively evaluated using MR, ultrasonography, and mammography. Imaging examinations were interpreted independently and blindly for implant rupture and correlated to operative findings. Surgical correlation in 16 patients (53 percent) with 31 implants showed 13 (42 percent) were intact, 5 (16 percent) had severe gel bleed, and 13 (42 percent) were ruptured. MR sensitivity was 100 percent and specificity was 63 percent. Accuracy for rupture was 81 percent with MR, higher than with ultrasonography and mammography (77 and 59 percent, respectively). We describe a specific pitfall in MR interpretation, the "rat-tail" sign, composed of a medial linear extension of silicone along the chest wall. Seen in eight cases (four intact, three ruptures, one gel bleed), the rat-tail sign may lead to misdiagnosis of implant rupture if seen in isolation. Magnetic resonance imaging is more accurate and sensitive than ultrasonography and mammography in detecting breast implant rupture. We describe a new sign (rat-tail sign) composed of medial compression of the implant simulating silicone extrusion as a potential false-positive MR finding for rupture. This article presents clinical experience with magnetic resonance, mammography, and ultrasound in the diagnosis of implant rupture and defines and illustrates potential pitfalls of MR interpretation, including the new rat-tail sign.
ISSN:0032-1052
DOI:10.1097/00006534-199912000-00016