Accurate Measurement of Near-Micromolar Oxygen Concentrations in Aqueous Solutions Based on Enzymatic Extradiol Cleavage of 4-Chlorocatechol: Applications to Improved Low-Oxygen Experimental Systems and Quantitative Assessment of Back Diffusion of Oxygen from the Atmosphere
An enzymatic method for measuring the O2 concentrations of aqueous solutions was developed by involving 4-chlorocatechol and catechol 2,3-dioxygenase from Pseudomo-nas putida. With this system, the amount of O2 in a sample solution can be measured as the amount of 5-chloro-2-hydroxymuconate semialde...
Saved in:
Published in | Journal of biochemistry (Tokyo) Vol. 131; no. 4; pp. 523 - 531 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
England
Oxford University Press
01.04.2002
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | An enzymatic method for measuring the O2 concentrations of aqueous solutions was developed by involving 4-chlorocatechol and catechol 2,3-dioxygenase from Pseudomo-nas putida. With this system, the amount of O2 in a sample solution can be measured as the amount of 5-chloro-2-hydroxymuconate semialdehyde formed through the enzyme reaction. The product was stable and its anion exhibited strong absorption around 380 nm (molar absorption coefficient of 4.3 x 104 M−1 cm−1, pK value of 5.4). A sensitive HPLC method involving a BioAssist Q column was developed to individually quantify the products derived from 4-chlorocatechol and catechol. When the O2 concentration in a sample solution sealed in a vial was lowered from the air-saturation level by means of the amount enzymatically reacted with a known amount of catechol, the concentration of remaining Oa could be successfully measured by the HPLC method. We developed devices through which reagents could be added to solutions sealed in cuvettes or the vessel of an oxygen electrode system under a flow of argon. By applying these devices, the submicromolar O2 concentration of an anoxdc solution and the back diffusion of O2 from the atmosphere could be directly determined for the first time. The Km values of the dioxygenase and an ascorbate oxddase for oxygen were also determined to be 7.2 (at pH 7.5) and 114 µM (at pH 6.5), respectively, at 25°C. |
---|---|
Bibliography: | ArticleID:131.4.523 1This work was supported in part by Grants-in-Aid for Scientific Research on Priority Areas (No 753) and for Encouragement of Young Scientists from the Ministry of Education, Culture, Sports, Science and Technology of Japan istex:DFC7869E3A22AF38CEA8904C14D8D17C73DA2767 ark:/67375/HXZ-P3L28MDL-M ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0021-924X |
DOI: | 10.1093/oxfordjournals.jbchem.a003130 |