The development and evaluation of an in-vitro shoulder simulator with active muscle simulation

The purpose of the present study was to develop a novel active in-vitro shoulder simulator to emulate all forms of planar and non-planar glenohumeral motions with active muscle simulation on cadaver specimens or shoulder models and to critically evaluate its performance. A physiologic shoulder simul...

Full description

Saved in:
Bibliographic Details
Published inScientific reports Vol. 13; no. 1; p. 4423
Main Authors Guo, Ruipeng, Ferle, Manuel, Nebel, Dennis, Hurschler, Christof
Format Journal Article
LanguageEnglish
Published England Nature Publishing Group 17.03.2023
Nature Publishing Group UK
Nature Portfolio
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The purpose of the present study was to develop a novel active in-vitro shoulder simulator to emulate all forms of planar and non-planar glenohumeral motions with active muscle simulation on cadaver specimens or shoulder models and to critically evaluate its performance. A physiologic shoulder simulator, driven using simulated muscle force, was developed to dynamically realize accurate kinematic control in all three rotational degrees of freedom (DOF) under physiological kinetic boundaries. The control algorithm of the simulator was implemented using three parallel running independent control loops, which regulate the forces of individual muscles in the respect DOF and work asynchronously in disparate sequences adapted to specific motions (abduction, flexion/extension and rotation). Three cadaveric specimens were used to evaluate the kinematic and kinetic performance of the simulator during simulated motions. High kinematic accuracy (maximum mean deviation ≤ 2.35° and RMSE 1.13°) and repeatability (maximum and average SD of ≤ 1.21° and 0.67°) were observed in all three rotational DOF investigated. The reliabilities of all individual muscle forces actuated in the simulator during planar and non-planar motions were generally excellent, with the 95% CIs of ICC estimates of > 0.90 for most instances (30/36). A novel shoulder simulator with active muscle simulation was developed and evaluated. Its capability to reproduce kinematics and kinetics in a physiological range for all DOF was systematically evaluated for multiple kinetic and kinematic outcome variables. The presented simulator is a powerful tool for investigating the biomechanics of physiological and pathological shoulder joints and to evaluate various surgical interventions. Acquisition of reliable data in joint kinetics and translational kinematics during active motions is critical to assess shoulder pathologies and appropriate treatments. We provide a unique muscle activated physiologic shoulder simulator, which allows the comprehensive acquisition of joint kinematic and kinetic data during repeated realistic planar and non-planar motions.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-023-31200-y