Relationship between the optic nerve sheath diameter and lumbar cerebrospinal fluid pressure in patients with normal tension glaucoma
Purpose To investigate on the relationship between the optic nerve sheath diameter (ONSD) and the lumbar cerebrospinal fluid pressure (CSF-p) in Caucasian patients with normal tension glaucoma (NTG). Patients and methods Retrospective analysis of medical records of patients with open-angle glaucoma...
Saved in:
Published in | Eye (London) Vol. 31; no. 9; pp. 1365 - 1372 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
London
Nature Publishing Group UK
01.09.2017
Nature Publishing Group |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Purpose
To investigate on the relationship between the optic nerve sheath diameter (ONSD) and the lumbar cerebrospinal fluid pressure (CSF-p) in Caucasian patients with normal tension glaucoma (NTG).
Patients and methods
Retrospective analysis of medical records of patients with open-angle glaucoma in the period from 2005 to 2015 from the Ophthalmology Department, Cantonal Hospital Aarau, Switzerland was performed. A total of 38 patients (mean age 68.6±11.3 years, 21 females and 17 males) fulfilled the diagnostic criteria of NTG and underwent computed tomography (CT) of the orbit and lumbar puncture (LP). In total, 38 age- and gender-matched Caucasian subjects (mean age: 68.9±10.9 years) without known ON diseases served as controls for ONSD measurements. ONSDs were measured at a distance of 3 mm from the posterior globe and lumbar CSF-p was related to the measurements. Statistical analysis was performed by using the independent two-tailed
t
-test and the non-parametric Spearman's correlation test.
Results
The mean ONSD in NTGs measured 6.4±0.9 mm and in controls 5.4±0.6 mm. The difference between NTGs and controls showed statistical significance (
t
-test:
P
<0.000). The mean CSF-p in NTG was 11.6±3.7 mm Hg. There was no statistical significant correlation between ONSD and CSF-p (Spearman's correlation coefficient
ρ
=0.06,
P
=0.72).
Conclusions
This study demonstrates enlarged ONSDs and normal lumbar CSF-p in 38 Caucasian NTG patients. As enlarged ONSDs generally are associated with increased intracranial CSF-p, these results can be explained by a disturbed communication of CSF-p between the intracranial and intraorbital subarachnoid spaces. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ISSN: | 0950-222X 1476-5454 1476-5454 |
DOI: | 10.1038/eye.2017.70 |