Evaluations of miniscrew type-dependent mechanical stability

Miniscrew has been widely used as an absolute anchorage in orthodontic treatment. Types of miniscrew with different diameter, length, shape, and thread dimensions may have a substantial effect on mechanical stability of the miniscrew system. Thus, the objective of this study was to evaluate miniscre...

Full description

Saved in:
Bibliographic Details
Published inClinical biomechanics (Bristol) Vol. 69; pp. 21 - 27
Main Authors Han, Cheol-Min, Watanabe, Keiichiro, Tsatalis, Andrea E., Lee, Damian, Zheng, Fengyuan, Kyung, Hee-Moon, Deguchi, Toru, Kim, Do-Gyoon
Format Journal Article
LanguageEnglish
Published England Elsevier Ltd 01.10.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Miniscrew has been widely used as an absolute anchorage in orthodontic treatment. Types of miniscrew with different diameter, length, shape, and thread dimensions may have a substantial effect on mechanical stability of the miniscrew system. Thus, the objective of this study was to evaluate miniscrew type-dependent mechanical stability to assess mechanical properties of miniscrew systems in various thickness of artificial bone block using different measurement tools. Two types of miniscrews (15 Tomas and 15 AbsoAnchor) were placed in artificial bone block with different thickness of 1.5, 2.0, 3.0 mm. Values of maximum insertion torque, removal torque, Periotest, implant stability quotient, static stiffness, dynamic stiffness, and energy dissipation ability were assessed for each miniscrew system. The maximum insertion torque, removal torque, implant stability quotient, static and dynamic stiffness values significantly increased when the miniscrews were placed in thicker bone block while Periotest values decreased. The static stiffness, Periotest and implant stability quotient values were significantly correlated each other and also with other mechanical properties (p < 0.001) except tan δ (p > 0.35). However, the slopes of some correlations and absolute values of measurement were significantly different dependent on the miniscrew types (p < 0.025). The current findings suggest that miniscrew type-dependent calibrations are required to estimate mechanical stability of the miniscrew systems despite the utilization of same measurement tool. •Stiffness, Periotest, implant stability quotient values of miniscrew systems were correlated.•Absolute values of measurement were different dependent on the miniscrew types.•Miniscrew type-dependent calibrations are required for each measurement tool.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0268-0033
1879-1271
DOI:10.1016/j.clinbiomech.2019.06.016