Improved DNA fragment length estimation in capillary electrophoresis

In CE the charged DNA strands are fractionated according to fragment lengths as they migrate through the capillary, since shorter DNA fragments pass through the sieving matrix faster. Multiplexed internal size standards are used to estimate the size of unknown DNA fragments. In the literature there...

Full description

Saved in:
Bibliographic Details
Published inElectrophoresis Vol. 29; no. 6; pp. 1273 - 1285
Main Authors Akbari, Akbar, Marthinsen, Gunnhild, Lifjeld, Jan T., Albregtsen, Fritz, Wennerberg, Liv, Stenseth, Nils C., Jakobsen, Kjetill S.
Format Journal Article
LanguageEnglish
Published Weinheim WILEY-VCH Verlag 01.03.2008
WILEY‐VCH Verlag
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In CE the charged DNA strands are fractionated according to fragment lengths as they migrate through the capillary, since shorter DNA fragments pass through the sieving matrix faster. Multiplexed internal size standards are used to estimate the size of unknown DNA fragments. In the literature there are statements about migration abnormalities for the 250 and 340 bp fragments in the GeneScan‐500 (GS500) internal size standards. Such anomalous migration of size standards could obviously introduce errors in the estimation of unknown fragments. Therefore, a number of analysis programs simply exclude some of these fragments. In the present work we first evaluate the effect of excluding each of the fragments in the internal size standards used in CE. Next, a method which is based on estimating the true values of the anomalous fragments is presented. The results obtained by the new method indicate a significant improvement compared to results obtained when one (or both) of the anomalous fragments in GS500 is (are) excluded or included when estimating the size of unknown DNA fragments. In the higher‐molecular‐weight region, the average error is reduced from 1.91 bp in ABI GeneMapper (excluding 250 bp) to 0.15 bp in the new method (using the estimated values for 250 and 340 bp). In the lower‐molecular‐weight region, excluding both fragments will improve the results by an average of 0.74 bp compared to ABI GeneMapper.
Bibliography:ark:/67375/WNG-NNMFDDFM-S
istex:44D78D86E1487D9CCFBA27E2B4290EA264ABF4AC
ArticleID:ELPS200700523
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0173-0835
1522-2683
DOI:10.1002/elps.200700523