Photometric method for dual targeting of surface and surface-associated proteins on extracellular vesicles in the multiparametric test

Extracellular vesicles (EVs) have become a topic of interest within the field of diagnostic biomarkers; however, recent developments in the study of EVs have increased the need for simpler but still comprehensive methods for characterization. Here, we describe how to simultaneously measure several s...

Full description

Saved in:
Bibliographic Details
Published inFrontiers in molecular biosciences Vol. 9; p. 917487
Main Authors Clegg, Lee-Ann Marie, Sloth, Jenni Kathrine, Bæk, Rikke, Jørgensen, Malene Møller
Format Journal Article
LanguageEnglish
Published Frontiers Media S.A 25.10.2022
Subjects
Online AccessGet full text
ISSN2296-889X
2296-889X
DOI10.3389/fmolb.2022.917487

Cover

More Information
Summary:Extracellular vesicles (EVs) have become a topic of interest within the field of diagnostic biomarkers; however, recent developments in the study of EVs have increased the need for simpler but still comprehensive methods for characterization. Here, we describe how to simultaneously measure several surface or surface-associated proteins on EVs using a multiparametric microarray-based analysis termed Extracellular Vesicle Array (EV Array), which is developed to catch and phenotypically characterize small EVs. Previously, this analysis has been limited to measuring only one fluorescent signal per analysis. The analysis relies on antibodies printed onto a solid surface, for catching the EVs carrying the specific surface or surface-associated proteins, and on the subsequent fluorescent detection. For the optimization of detection, two antibodies with attached Cy3 or Cy5 were added to various combinations of the EV surface or surface-associated proteins: CD9, CD63, CD81, flotillin-1, and HSP90. In this study, the EV surface or surface-associated proteins were analyzed in human plasma from six healthy subjects. Changes observed in signal intensities from Cy3 and Cy5 related specifically to these combinations and allowed for a comparison of the two different fluorescent signals. When comparing the results, it was observed that it is possible to measure the EV surface or surface-associated proteins at both 532 nm (Cy3) and 635 nm (Cy5) simultaneously without a significant change in signals from the detection molecules. This allows us to measure multiple EV marker proteins in a single analysis, thereby more quickly finding complex biomarker patterns in a sample.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Navnit Kumar Mishra, Chandigarh University, India
Edited by: Dwijendra K. Gupta, Allahabad University, India
Kaushlendra Tripathi, University of Alabama at Birmingham, United States
This article was submitted to Cellular Biochemistry, a section of the journal Frontiers in Molecular Biosciences
Reviewed by: Aleksander Czogalla, University of Wrocław, Poland
ISSN:2296-889X
2296-889X
DOI:10.3389/fmolb.2022.917487