Safety and audiological outcome in a case series of tertiary therapy of sudden hearing loss with a biodegradable drug delivery implant for controlled release of dexamethasone to the inner ear
Background Intratympanic injections of glucocorticoids have become increasingly common in the treatment of idiopathic sudden sensorineural hearing loss (ISSHL). However, due to their fast elimination, sustained applications have been suggested for local drug delivery to the inner ear. Materials and...
Saved in:
Published in | Frontiers in neuroscience Vol. 16; p. 892777 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Frontiers Media S.A
20.09.2022
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background
Intratympanic injections of glucocorticoids have become increasingly common in the treatment of idiopathic sudden sensorineural hearing loss (ISSHL). However, due to their fast elimination, sustained applications have been suggested for local drug delivery to the inner ear.
Materials and methods
The study is based on a retrospective chart review of patients treated for ISSHL at a single tertiary (university) referral center. We included patients who were treated with a solid, biodegradable, poly(D,L-lactic-co-glycolic acid) (PLGA)-based drug delivery system providing sustained delivery of dexamethasone extracochlear into the round window niche (
n
= 15) or intracochlear into scala tympani (
n
= 2) for tertiary therapy of ISSHL in patients without serviceable hearing after primary systemic and secondary intratympanic glucocorticoid therapy. We evaluated the feasibility and safety through clinical evaluation, histological examination, and functional tests [pure-tone threshold (PTA), word recognition scores (WRS)].
Results
With adequate surgical preparation of the round window niche, implantation was feasible in all patients. Histologic examination of the material in the round window niche showed signs of resorption without relevant inflammation or foreign body reaction to the implant. In patients where the basal part of scala tympani was assessable during later cochlear implantation, no pathological findings were found. In the patients with extracochlear application, average preoperative PTA was 84.7 dB HL (SD: 20.0) and 76.7 dB HL (SD: 16.7) at follow-up (
p
= 0.08). The preoperative average maximum WRS was 14.6% (SD: 17.9) and 39.3% (SD: 30.7) at follow-up (
p
= 0.11). Six patients (40%), however, reached serviceable hearing. The two patients with intracochlear application did not improve.
Conclusion
The extracochlear application of the controlled release system in the round window niche and – based on limited observations - intracochlear implantation into scala tympani appears feasible and safe. Due to the uncontrolled study design, conclusions about the efficacy of the treatment are limited. These observations, however, may encourage the initiation of prospective controlled studies using biodegradable controlled release implants as drug delivery systems for the treatment of inner ear diseases. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 This article was submitted to Neuropharmacology, a section of the journal Frontiers in Neuroscience Edited by: Peter S. Steyger, Creighton University, United States Reviewed by: Agnieszka J. Szczepek, Charité - Universitätsmedizin Berlin, Germany; Esperanza Bas Infante, University of Miami, United States |
ISSN: | 1662-453X 1662-4548 1662-453X |
DOI: | 10.3389/fnins.2022.892777 |