Optimization of parameters through Taguchi method for enhanced corrosion inhibition of poly (vinyl alcohol-serine)

Parametric optimization was carried out for the mixture of polyvinyl alcohol (PVA) and l-serine using Taguchi statistical approach. L 9 orthogonal array of experiments were designed and the results were analyzed with Qualitek software. Synergistic effect of the mixture was enhanced at the Qualitek p...

Full description

Saved in:
Bibliographic Details
Published inJournal of adhesion science and technology Vol. 29; no. 24; pp. 2648 - 2678
Main Authors Fathima Sabirneeza, A. Ali, Subhashini, S., Shahul Hameed, A.
Format Journal Article
LanguageEnglish
Published Utrecht Taylor & Francis 17.12.2015
Taylor & Francis Ltd
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Parametric optimization was carried out for the mixture of polyvinyl alcohol (PVA) and l-serine using Taguchi statistical approach. L 9 orthogonal array of experiments were designed and the results were analyzed with Qualitek software. Synergistic effect of the mixture was enhanced at the Qualitek predicted optimized conditions. The graft polymer, poly(vinyl alcohol-serine) (PVAS), was synthesized using free radical-initiated reactions of l-serine with PVA in order to achieve effective inhibition. PVAS was characterized using Fourier transform infrared spectroscopy, scanning electron microscopy, and powder X-ray diffraction analysis. The thermal properties of PVAS were studied by thermogravimetry, differential thermal analysis, and differential scanning calorimetry. The corrosion inhibition property of PVAS on mild steel corrosion was continuously monitored using electrochemical techniques. Temperature effect on the inhibition properties of PVAS was studied using electrochemical and gravimetric measurements. AFM studies confirmed the formation of polymeric film on mild steel surface which inhibits the rate of corrosion. Theoretical calculations using Hyperchem 7.0 proved the better corrosion mitigation properties of PVAS compared to PVA. The experimental results and surface analysis confirmed the effective inhibition process of the graft polymer which was also supported by the theoretical calculations. A good correlation was obtained between the results of the electrochemical measurements, conventional gravimetric measurement, surface analysis, and theoretical calculations. All the studies proved the enhanced corrosion inhibition properties of PVA through grafting of polyserine.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0169-4243
1568-5616
DOI:10.1080/01694243.2015.1078922