Study of detection times for liver stiffness evaluation by shear wave elastography

AIM:To investigate enough valid measurements(VMs)to assess liver fibrosis in chronic hepatitis B patients(CHB).METHODS:One hundred and twelve CHB patients(25women,87 men)with a mean age of 38.43 years received liver stiffness evaluations using real-time shear wave elastography for 10 VMs.All patient...

Full description

Saved in:
Bibliographic Details
Published inWorld journal of gastroenterology : WJG Vol. 20; no. 28; pp. 9578 - 9584
Main Authors Huang, Ze-Ping, Zhang, Xin-Ling, Zeng, Jie, Zheng, Jian, Wang, Ping, Zheng, Rong-Qin
Format Journal Article
LanguageEnglish
Published United States Baishideng Publishing Group Inc 28.07.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:AIM:To investigate enough valid measurements(VMs)to assess liver fibrosis in chronic hepatitis B patients(CHB).METHODS:One hundred and twelve CHB patients(25women,87 men)with a mean age of 38.43 years received liver stiffness evaluations using real-time shear wave elastography for 10 VMs.All patients underwent liver biopsy.Based on the biopsy pathology,the liver stiffness data obtained from different VMs(1,2,3,5and 10 times)were compared for the evaluation of liver fibrosis.The correlation between the elastic modulus means of the liver obtained from different VMs of detection at each pathological stage was analysed.The receiver operating characteristic(ROC)curve was employed to determine the diagnostic performance of different VMs of detection,and the areas under the ROC curve of different groups were compared.RESULTS:The liver stiffness values obtained from 1 VM,2 VMs,3 VMs,5 VMs and all 10 VMs for stage F0 were 6.95±2.01 kPa,6.87±1.83 kPa,6.90±1.88 kPa,6.95±1.93kPa and 7.15±1.89 kPa,respectively(F=0.043,P=0.996).For stage F1,these values were 7.12±1.72 kPa,7.24±1.72 kPa,7.21±1.74 kPa,7.10±1.78 kPa and7.04±1.70 kPa,respectively(F=0.075,P=0.990).For stage F2,they were 9.37±3.87 kPa,9.18±3.68 kPa,9.19±3.81 kPa,9.18±3.81 kPa and 9.19±3.53 kPa,respectively(F=0.012,P=1.000).For stage F3,these were 11.91±3.88 kPa,11.78±4.04 kPa,11.83±4.07kPa,11.94±4.17 kPa and 12.00±4.02 kPa,respectively(F=0.010,P=1.000).For stage F4,the readings were 19.30±7.63 kPa,19.40±7.36 kPa,19.54±7.43kPa,19.73±7.21 kPa and 20.25±7.22 kPa,respectively(F=0.054,P=0.995).There were no significant differences between these groups.Intraclass correlation coefficients among different pathological stages(F0-F4)with different detection VMs were 0.995,0.993,0.996,0.994 and 0.996,respectively.The mean elasticity values from 1 VM,2 VMs,3 VMs,5 VMs and 10 VMs can accurately distinguish fibrosis stages(F0 vs F1234,F01 vs F234,F012 vs F34 and F0123 vs F4)with no significant differences in the five groups(P>0.05 for all).CONCLUSION:One VM may be sufficient to assess liver fibrosis by using SWE without any significant loss of accuracy in patients with CHB.However,future studies of larger patient samples are necessary for the validation of this method.
Bibliography:Ze-Ping Huang;Xin-Ling Zhang;Jie Zeng;Jian Zheng;Ping Wang;Rong-Qin Zheng;Department of Medical Ultrasonics,the Third Affiliated Hospital of Sun Yat-sen University
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Undefined-3
Telephone: +86-20-85253030 Fax: +86-20-85252416
Author contributions: Huang ZP and Zhang XL contributed equally to this work; Huang ZP and Zhang XL performed the majority of experiments and wrote the manuscript; Zeng J and Zheng J detected the patients and collected the data for this work; Wang P was involved in editing the manuscript; Zheng RQ designed the study.
Correspondence to: Rong-Qin Zheng, MD, PhD, Department of Medical Ultrasonics, the Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630, Guangdong Province, China. zhengrongqin@hotmail.com
ISSN:1007-9327
2219-2840
2219-2840
DOI:10.3748/wjg.v20.i28.9578