Can noninvasive hemoglobin measurement reduce the need for preoperative venipuncture in pediatric outpatient surgery?

Summary Background Noninvasive measurements of hemoglobin in the pediatric perioperative setting could be helpful to avoid venipunctures in children. The present study aims to evaluate this by using a noninvasive device for hemoglobin determination. We compared noninvasively obtained hemoglobin with...

Full description

Saved in:
Bibliographic Details
Published inPediatric anesthesia Vol. 27; no. 11; pp. 1131 - 1135
Main Authors Zeng, Ruifeng, Svensen, Christer H., Li, Husong, Xu, Ximou, Skoog Svanberg, Agneta, Liu, Huacheng, Li, Yanrong, Shangguan, Wangning, Lian, Qingquan, Lerman, Jerrold
Format Journal Article
LanguageEnglish
Published France Wiley Subscription Services, Inc 01.11.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Summary Background Noninvasive measurements of hemoglobin in the pediatric perioperative setting could be helpful to avoid venipunctures in children. The present study aims to evaluate this by using a noninvasive device for hemoglobin determination. We compared noninvasively obtained hemoglobin with laboratory hemoglobin concentrations in children during their preoperative assessment. Methods In an observational study, 122 nonanemic children (age 4.2 ± 1.6 years) who were scheduled to undergo different surgical procedures under general anesthesia were included. In their preoperative preparations, single invasive blood samples for laboratory hemoglobin concentrations were routinely taken following hospital policy and compared to simultaneous noninvasive determinations of hemoglobin. A preoperative invasive value ≤9 g/dL would have caused cancelation of surgery and implied further investigations. Results A Bland‐Altman plot showed that the average difference between noninvasively obtained hemoglobin and laboratory hemoglobin concentration was −0.44 g/dL (bias) with a standard deviation of the mean bias of 1.04 g/dL. A hemoglobin error grid showed that the noninvasive device could identify almost all invasive hemoglobin values >9 g/dL. In total, there were 4 false‐positive values where noninvasively obtained hemoglobin observations were below while the paired invasive values were above 9 g/dL. Conclusion The data in this pediatric setting suggest that the device may eliminate the need for venipuncture in nonanemic children.
Bibliography:Funding information
Department of Health, Zhejiang Province, WKJ2010‐2‐017 (Qingquan Lian), 2012RCA044 (Ruifeng Zeng) and 2012RCA045 (Wangning Shangguan); International exchange program of Health and Family Planning Commission of Zhejiang Province, 2014116 (Ruifeng Zeng); The Zhejiang Province Public Welfare Technology Foundation of China 2015C33100 (Huacheng Liu); Zhejiang Medical Supported Discipline (Anesthesiology, 201602, Ruifeng Zeng) and Wenzhou City Public Welfare Science and Technology Project (Y20170138, Ruifeng Zeng).
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:1155-5645
1460-9592
1460-9592
DOI:10.1111/pan.13229