Conventional detection of 2,4-dinitrophenol using quartz crystal microbalance
We present conventional detection of 2,4-dinitrophenol (DNP) for using the competitive reaction between DNP and DNP-conjugated albumin onto DNP antibody immobilized quartz crystal microbalance (QCM). This QCM method allows detection of DNP concentration in the range of 0.01 to 100 ng/ml; linear corr...
Saved in:
Published in | IEEE transactions on ultrasonics, ferroelectrics, and frequency control Vol. 50; no. 2; pp. 193 - 195 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
New York, NY
IEEE
01.02.2003
Institute of Electrical and Electronics Engineers The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | We present conventional detection of 2,4-dinitrophenol (DNP) for using the competitive reaction between DNP and DNP-conjugated albumin onto DNP antibody immobilized quartz crystal microbalance (QCM). This QCM method allows detection of DNP concentration in the range of 0.01 to 100 ng/ml; linear correlation obtains DNP concentration from 1 to 100 ng/ml. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 0885-3010 1525-8955 |
DOI: | 10.1109/TUFFC.2003.1182123 |