An artificial intelligence-based noninvasive solution to estimate pulmonary artery pressure

Aims Design to develop an artificial intelligence (AI) algorithm to accurately predict the pulmonary artery pressure (PAP) waveform using non-invasive signal inputs. Methods and results We randomly sampled training, validation, and testing datasets from a waveform database containing 180 patients wi...

Full description

Saved in:
Bibliographic Details
Published inFrontiers in cardiovascular medicine Vol. 9; p. 855356
Main Authors Zheng, Jianwei, Abudayyeh, Islam, Mladenov, Georgi, Struppa, Daniele, Fu, Guohua, Chu, Huimin, Rakovski, Cyril
Format Journal Article
LanguageEnglish
Published Frontiers Media S.A 24.08.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Aims Design to develop an artificial intelligence (AI) algorithm to accurately predict the pulmonary artery pressure (PAP) waveform using non-invasive signal inputs. Methods and results We randomly sampled training, validation, and testing datasets from a waveform database containing 180 patients with pulmonary atrial catheters (PACs) placed for PAP waves collection. The waveform database consisted of six hemodynamic parameters from bedside monitoring machines, including PAP, artery blood pressure (ABP), central venous pressure (CVP), respiration waveform (RESP), photoplethysmogram (PPG), and electrocardiogram (ECG). We trained a Residual Convolutional Network using a training dataset containing 144 (80%) patients, tuned learning parameters using a validation set including 18 (10%) patients, and tested the performance of the method using 18 (10%) patients, respectively. After comparing all multi-stage algorithms on the testing cohort, the combination of the residual neural network model and wavelet scattering transform data preprocessing method attained the highest coefficient of determination R 2 of 90.78% as well as the following other performance metrics and corresponding 95% confidence intervals (CIs): mean square error of 11.55 (10.22–13.5), mean absolute error of 2.42 (2.06–2.85), mean absolute percentage error of 0.91 (0.76–1.13), and explained variance score of 90.87 (85.32–93.31). Conclusion The proposed analytical approach that combines data preprocessing, sampling method, and AI algorithm can precisely predict PAP waveform using three input signals obtained by noninvasive approaches.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Edited by: Daniel Rueckert, Technical University of Munich, Germany
Reviewed by: Pedro A. Moreno-Sanchez, Tampere University, Finland; Zhichao Hao, University of Alabama, United States
This article was submitted to Heart Failure and Transplantation, a section of the journal Frontiers in Cardiovascular Medicine
ISSN:2297-055X
2297-055X
DOI:10.3389/fcvm.2022.855356