Considerations for metallographic observation of intergranular attack in Alloy 600 steam generator tubes
This technical note provides some considerations for the metallographic observation of intergranular attack (IGA) in Alloy 600 steam generator tubes. The IGA region was crazed along the grain boundaries through a deformation by an applied stress. The direction and extent of the crazing depended on t...
Saved in:
Published in | Nuclear engineering and technology Vol. 47; no. 7; pp. 934 - 938 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Elsevier B.V
01.12.2015
Elsevier 한국원자력학회 |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | This technical note provides some considerations for the metallographic observation of intergranular attack (IGA) in Alloy 600 steam generator tubes. The IGA region was crazed along the grain boundaries through a deformation by an applied stress. The direction and extent of the crazing depended on those of the applied stress. It was found that an IGA defect can be misevaluated as a stress corrosion crack. Therefore, special caution should be taken during the destructive examination of the pulled-out tubes from operating steam generators. |
---|---|
Bibliography: | G704-000135.2015.47.7.005 |
ISSN: | 1738-5733 2234-358X |
DOI: | 10.1016/j.net.2015.09.003 |