Sterility maintenance study: Dynamic evaluation of sterilized rigid containers and wrapped instrument trays to prevent bacterial ingress

Background Sterilized packaging systems are designed to maintain the sterility of surgical instruments and devices from the time of sterilization until use. This study evaluated the effectiveness of rigid containers versus wrapped instrument trays, sterilized using North American sterilization proto...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of infection control Vol. 43; no. 12; pp. 1336 - 1341
Main Authors Shaffer, Harry L., MS, Harnish, Delbert A., MS, McDonald, Michael, MS, Vernon, Reid A., BS, Heimbuch, Brian K., MS
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.12.2015
Mosby-Year Book, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Sterilized packaging systems are designed to maintain the sterility of surgical instruments and devices from the time of sterilization until use. This study evaluated the effectiveness of rigid containers versus wrapped instrument trays, sterilized using North American sterilization protocols, to maintain a sterile internal environment poststerilization when challenged with aerosolized bacteria under dynamic environmental conditions. Methods Using a custom aerosol chamber, 111 rigid containers of various durations of use (unused, used <5 years, used 5-9 years) and 161 wrapped trays using 3 grades of sterilization wrap were challenged with ∼102 colony-forming units per liter of air containing aerosolized Micrococcus luteus with a count median particle size of 1 μm, while simultaneously experiencing air volume exchanges due to vacuum cycles–two 1-psi cycles, three 0.7-psi cycles, and three 0.4-psi cycles–to simulate air exchange events occurring during the sterilization, transportation, and storage of sterilized instrument trays in health care facilities. Results Of 111 rigid containers tested, 97 (87%) demonstrated bacterial ingress into the container. Of 161 wrapped trays, 0 (0%) demonstrated bacterial ingress into the tray. Contamination rates of rigid containers increased significantly with increasing duration of use. Conclusions In this study using a dynamic bacterial aerosol challenge, sterilized wrapped trays demonstrated significantly greater protection than sterilized rigid containers against the ingress of airborne bacteria.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0196-6553
1527-3296