Complication Rate of Transfemoral Endomyocardial Biopsy with Fluoroscopic and Two-dimensional Echocardiographic Guidance: A 10-Year Experience of 228 Consecutive Procedures

Endomyocardial biopsy (EMB) is one of the reliable methods for the diagnosis of various cardiac diseases. However, EMB can cause various complications. The purpose of this study is to evaluate the complication of transfemoral EMB with both fluoroscopic and two-dimensional (2-D) echocardiographic gui...

Full description

Saved in:
Bibliographic Details
Published inJournal of Korean medical science Vol. 28; no. 9; pp. 1323 - 1328
Main Authors Jang, Se Yong, Cho, Yongkeun, Song, Joon Hyuck, Cheon, Sang Soo, Park, Sun Hee, Bae, Myung Hwan, Lee, Jang Hoon, Yang, Dong Heon, Park, Hun Sik, Chae, Shung Chull
Format Journal Article
LanguageEnglish
Published Korea (South) The Korean Academy of Medical Sciences 01.09.2013
대한의학회
Subjects
Online AccessGet full text
ISSN1011-8934
1598-6357
1598-6357
DOI10.3346/jkms.2013.28.9.1323

Cover

Loading…
More Information
Summary:Endomyocardial biopsy (EMB) is one of the reliable methods for the diagnosis of various cardiac diseases. However, EMB can cause various complications. The purpose of this study is to evaluate the complication of transfemoral EMB with both fluoroscopic and two-dimensional (2-D) echocardiographic guidance. A total of 228 patients (148 men; 46.0±14.6 yr-old) who underwent EMB at Kyungpook National University Hospital from January 2002 to June 2012 were included. EMB was performed via the right femoral approach with the guidance of both echocardiography and fluoroscopy. Overall, EMB-related complications occurred in 21 patients (9.2%) including one case (0.4%) with cardiac tamponade requiring emergent pericardiocentesis, four cases (1.8%) with small pericardial effusion without pericardiocentesis, two cases (0.9%) with hemodynamically unstable ventricular tachycardia (VT), one case (0.4%) with nonsustained VT, one case (0.4%) with tricuspid regurgitation, twelve cases (5.3%) with right bundle branch block. There was no occurrence of either EMB-related death or cardiac surgery. Left ventricular ejection fraction was significantly lower (32.0±18.7% vs 42.0±19.1%, P=0.023) and left ventricular end-diastolic dimension was larger (60.0±10.0 mm vs 54.2±10.2 mm, P=0.013) in patients with EMB related complications than in those without. It is concluded that transfemoral EMB with fluoroscopic and 2-D echocardiographic guidance is a safe procedure with low complication rate.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
G704-000345.2013.28.9.007
ISSN:1011-8934
1598-6357
1598-6357
DOI:10.3346/jkms.2013.28.9.1323