Assessment of a Standardized ROS Production Profile in Humans by Electron Paramagnetic Resonance

Despite the growing interest in the role of reactive oxygen species (ROS) in health and disease, reliable quantitative noninvasive methods for the assessment of oxidative stress in humans are still lacking. EPR technique, coupled to a specific spin probe (CMH: 1-hydroxy-3-methoxycarbonyl-2,2,5,5-tet...

Full description

Saved in:
Bibliographic Details
Published inOxidative medicine and cellular longevity Vol. 2012; no. 2012; pp. 1 - 10
Main Authors Mrakic-Sposta, Simona, Gussoni, Maristella, Montorsi, Michela, Porcelli, Simone, Vezzoli, Alessandra
Format Journal Article
LanguageEnglish
Published Cairo, Egypt Hindawi Puplishing Corporation 01.01.2012
Hindawi Publishing Corporation
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Despite the growing interest in the role of reactive oxygen species (ROS) in health and disease, reliable quantitative noninvasive methods for the assessment of oxidative stress in humans are still lacking. EPR technique, coupled to a specific spin probe (CMH: 1-hydroxy-3-methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine) is here presented as the method of choice to gain a direct measurement of ROS in biological fluids and tissues. The study aimed at demonstrating that, differently from currently available “a posteriori” assays of ROS-induced damage by means of biomolecules (e.g., proteins and lipids) spin-trapping EPR provides direct evidence of the “instantaneous” presence of radical species in the sample and, as signal areas are proportional to the number of excited electron spins, lead to absolute concentration levels. Using a recently developed bench top continuous wave system (e-scan EPR scanner, Bruker) dealing with very low ROS concentration levels in small (50 μL) samples, we successfully monitored rapid ROS production changes in peripheral blood of athletes after controlled exercise and sedentary subjects after antioxidant supplementation. The correlation between EPR results and data obtained by various enzymatic assays (e.g., protein carbonyls and thiobarbituric acid reactive substances) was determined too. Synthetically, our method allows reliable, quick, noninvasive quantitative determination of ROS in human peripheral blood.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
Academic Editor: Steve R. McAnulty
ISSN:1942-0900
1942-0994
1942-0994
DOI:10.1155/2012/973927