The Mechanical Effect of Rod Contouring on Rod-Screw System Strength in Spine Fixation

Rod-screw fixation systems are widely used for spinal instrumentation. Although many biomechanical studies on rod-screw systems have been carried out, but the effects of rod contouring on the construct strength is still not very well defined in the literature. This work examines the mechanical impac...

Full description

Saved in:
Bibliographic Details
Published inJournal of Korean Neurosurgical Society Vol. 59; no. 5; pp. 425 - 429
Main Authors Acar, Nihat, Karakasli, Ahmet, Karaarslan, Ahmet A, Ozcanhan, Mehmet Hilal, Ertem, Fatih, Erduran, Mehmet
Format Journal Article
LanguageEnglish
Published Korea (South) The Korean Neurosurgical Society 01.09.2016
대한신경외과학회
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Rod-screw fixation systems are widely used for spinal instrumentation. Although many biomechanical studies on rod-screw systems have been carried out, but the effects of rod contouring on the construct strength is still not very well defined in the literature. This work examines the mechanical impact of straight, 20° kyphotic, and 20° lordotic rod contouring on rod-screw fixation systems, by forming a corpectomy model. The corpectomy groups were prepared using ultra-high molecular weight polyethylene samples. Non-destructive loads were applied during flexion/extension and torsion testing. Spine-loading conditions were simulated by load subjections of 100 N with a velocity of 5 mm min(-1), to ensure 8.4-Nm moment. For torsional loading, the corpectomy models were subjected to rotational displacement of 0.5° s(-1) to an end point of 5.0°, in a torsion testing machine. Under both flexion and extension loading conditions the stiffness values for the lordotic rod-screw system were the highest. Under torsional loading conditions, the lordotic rod-screw system exhibited the highest torsional rigidity. We concluded that the lordotic rod-screw system was the most rigid among the systems tested and the risk of rod and screw failure is much higher in the kyphotic rod-screw systems. Further biomechanical studies should be attempted to compare between different rod kyphotic angles to minimize the kyphotic rod failure rate and to offer a more stable and rigid rod-screw construct models for surgical application in the kyphotic vertebrae.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
G704-001031.2016.59.5.013
ISSN:2005-3711
1598-7876
DOI:10.3340/jkns.2016.59.5.425