Ultrasound-guided liver biopsy in real life: Comparison of same-day prebiopsy versus real-time ultrasound approach

Background and Aim:  Currently, an increasing number of liver biopsies are performed by radiologists under real‐time ultrasound control. A routine ultrasound assessment of a puncture site before performing percutaneous biopsy is reported to increase diagnostic yield and decrease complication rates....

Full description

Saved in:
Bibliographic Details
Published inJournal of gastroenterology and hepatology Vol. 22; no. 9; pp. 1490 - 1493
Main Authors Manolakopoulos, Spilios, Triantos, Christos, Bethanis, Sotirios, Theodoropoulos, Jiannis, Vlachogiannakos, Jiannis, Cholongitas, Evangelos, Sideridis, Markos, Barbatis, Calipso, Piperopoulos, Ploutarchos, Spiliadi, Charis, Papadimitriou, Nikolaos, Roukounakis, Nikolaos, Tzourmakliotis, Dimitrios, Avgerinos, Alec, Burroughs, Andrew
Format Journal Article
LanguageEnglish
Published Melbourne, Australia Blackwell Publishing Asia 01.09.2007
Blackwell Science
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background and Aim:  Currently, an increasing number of liver biopsies are performed by radiologists under real‐time ultrasound control. A routine ultrasound assessment of a puncture site before performing percutaneous biopsy is reported to increase diagnostic yield and decrease complication rates. It is not clear if real‐time ultrasound is superior to marking the puncture site before biopsy as regards reducing biopsy size and avoiding fragmentation and complications. The aim of this study was to compare ultrasound assessment of the puncture site before performing percutaneous liver biopsy with real‐time ultrasound liver biopsy for suspected diffuse liver disease. Methods:  Consecutive percutaneous liver biopsies (n = 631) for diffuse liver disease were evaluated. Group A consisted of patients who had real‐time guided‐ultrasound biopsy performed by radiologists (241 patients; M/F, 35/106; median age 48 year [range, 17–76]; needle 18 G). Group B patients were assessed by radiologists using ultrasound of the puncture site on the same day that biopsies were performed by experienced gastroenterologists/hepatologists on the ward using the marked site (390 patients; M/F, 276/114; median age 43 year [range, 15–75]; needle 16 G). Results:  There were no differences in severity of liver disease, establishing a diagnosis (OR, 1.92 [95% CI, 0.84–4.34]; P = 0.12), length of liver biopsy specimens, number of fragments or complications. Two independent variables were significantly associated with a histological diagnosis: longer biopsy length (P < 0001) and fragment number of two or less (P < 0.001). Conclusion:  Real‐time ultrasound did not improve diagnostic yield or result in fewer complications. Marking the puncture site seems adequate and has the practical advantage that it takes up less of the radiologists' time.
Bibliography:istex:9A63C156D08DD4957C85602329EA506A1810A166
ArticleID:JGH4992
ark:/67375/WNG-05QC8JVZ-2
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0815-9319
1440-1746
DOI:10.1111/j.1440-1746.2007.04992.x