Evaluation of the incident directional dependence of radiochromic film by use of Monte Carlo simulation and measurement

In high-precision radiotherapy, absolute and relative doses are evaluated for patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). In our institution, we use GAFCHROMIC EBT3 (EBT3) for relative dose evaluation in IMRT QA. We usually use two directional film configura...

Full description

Saved in:
Bibliographic Details
Published inRadiological physics and technology Vol. 9; no. 2; pp. 227 - 232
Main Authors Yuasa, Yuki, Kawamura, Shinji, Shiinoki, Takehiro, Uehara, Takuya, Koike, Masahiro, Kanzaki, Ryuji, Hanazawa, Hideki, Takahashi, Shotaro, Shibuya, Keiko
Format Journal Article
LanguageEnglish
Published Tokyo Springer Japan 01.07.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In high-precision radiotherapy, absolute and relative doses are evaluated for patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). In our institution, we use GAFCHROMIC EBT3 (EBT3) for relative dose evaluation in IMRT QA. We usually use two directional film configurations, which are in the axial and sagittal planes. The QA in our institution shows some differences between the gamma pass rates in the axial and sagittal directions. The purpose of this study was to evaluate the incident directional dependence of EBT3 by using the percent depth dose (PDD) and the off-center ratio (OCR) between EBT3 films positioned perpendicular to the beam axis and along the beam axis. Furthermore, we compared the PDD in EBT3 films positioned perpendicular to the beam axis and the PDD by using an ionization chamber. In addition, PDDs in water phantoms with and without EBT3 films were calculated by Monte Carlo simulation. The results showed that the PDD in EBT3 films positioned perpendicular to the beam axis increased with the depth from the phantom surface. Monte Carlo simulation showed the same trend as did the film measurements. The OCR results were slightly different at dose levels below 20 %. The OCR in EBT3 films positioned along the beam axis was higher than that perpendicular to the beam axis. Thus, we conclude that EBT3 film has incident directional dependence. In IMRT QA, the gamma analysis results may be affected by the incident directional dependence of EBT3 film.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1865-0333
1865-0341
DOI:10.1007/s12194-016-0353-6