Manometry of the normal upper esophageal sphincter and its alterations in laryngectomy

Rapid pull-through pressure profiles of the normal human upper esophageal sphincter (UES) were simultaneously studied with a conventional three-orifice Honeywell solid-state probe, an eight lumen radially perfused (RP) probe, and a circumferentially sensitive (CS) probe designed to measure UES press...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of clinical investigation Vol. 63; no. 5; pp. 1036 - 1041
Main Authors Welch, R W, Luckmann, K, Ricks, P M, Drake, S T, Gates, G A
Format Journal Article
LanguageEnglish
Published United States 01.05.1979
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Rapid pull-through pressure profiles of the normal human upper esophageal sphincter (UES) were simultaneously studied with a conventional three-orifice Honeywell solid-state probe, an eight lumen radially perfused (RP) probe, and a circumferentially sensitive (CS) probe designed to measure UES pressure (UESP) without regard to probe orientation. Pressure curves were digitized and analyzed by computer. The Honeywell probe recorded significantly lower peak pressures than the other two methods, and had wide intrasubject pressure variations (average coefficient of variation, 53%). In contrast, UESP measured with the CS probe was constant for each subject (mean peak UESP, 121 mm Hg; average coefficient of variation, 15%). Anteroposterior RP probe UESP were identical to CS probe pressures. Thus, peak perfused anteroposterior UESP correlates with circumferentially measured sphincter squeeze.Computer programs were written that allowed RP probe pressures to be mapped in three dimensions. Normal three-dimensional maps were characterized by anteroposterior accentuation of peak pressures and also by consistent axial asymmetry with anterior peak pressures occurring 0.8+/-0.2 cm closer to the pharynx. After defining the normal two- and three-dimensional UESP configuration, patients who had undergone laryngectomy were studied. Peak pressures measured with the RP probe decreased to congruent with50 mm Hg and radial pressure asymmetry vanished. Like normals, CS probe pressures corresponded to peak RP probe pressures. UES length did not change significantly. Three-dimensional mapping showed that axial asymmetry also vanished. It therefore appears that the anatomic alterations produced by laryngectomy abolishes UESP asymmetry.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0021-9738
DOI:10.1172/jci109372