Pragmatic accuracy of an in-house loop-mediated isothermal amplification (LAMP) for diagnosis of pulmonary tuberculosis in a Thai community hospital

Background To improve the quality of diagnosing pulmonary tuberculosis (TB), WHO recommends the use of rapid molecular testing as an alternative to conventional microscopic methods. Loop-mediated isothermal amplification assay (LAMP test) is a practical and cost-effective nucleic amplification techn...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 15; no. 7; p. e0236496
Main Authors Toonkomdang, Sarawut, Phinyo, Phichayut, Phetsuksiri, Benjawan, Patumanond, Jayanton, Rudeeaneksin, Janisara, Klayut, Wiphat
Format Journal Article
LanguageEnglish
Published San Francisco Public Library of Science 23.07.2020
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background To improve the quality of diagnosing pulmonary tuberculosis (TB), WHO recommends the use of rapid molecular testing as an alternative to conventional microscopic methods. Loop-mediated isothermal amplification assay (LAMP test) is a practical and cost-effective nucleic amplification technique. We evaluated the pragmatic accuracy of an in-house LAMP assay for the diagnosis of TB in a remote health care setting where an advanced rapid molecular test is not available. Methods A prospective diagnostic accuracy study was conducted. Patients with clinical symptoms suggestive of TB were consecutively enrolled from April to August 2016. Sputum samples were collected from each patient and were sent for microscopic examination (both acid-fast stain and fluorescence stain), in-house LAMP test, and TB culture. Results One hundred and seven patients with TB symptoms were used in the final analysis. This included 50 (46.7%) culture-positive TB patients and 57 (53.3%) culture-negative patients. The overall sensitivity of the in-house LAMP based on culture positivity was 88.8% (95/107) with a 95%CI of 81.2–94.1. The sensitivity was 90.9% (40/44) with a 95%CI of 78.3–97.5 for smear-positive, culture-positive patients, and was 16.7% (1/6) with a 95%CI of 0.4–64.1 for smear-negative, culture-positive patients. The overall sensitivity of the in-house LAMP test compared to smear microscopy methods were not significantly different (p = 0.375). The specificity of the in-house LAMP based on non-TB patients (smear-negative, culture-negative) was 94.7% (54/57) with a 95%CI of 85.4–98.9. Conclusions The diagnostic accuracy of the in-house LAMP test in a community hospital was comparable to other previous reports in terms of specificity. The sensitivity of the in-house assay could be improved with better sputum processing and DNA extraction method.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Competing Interests: The authors have declared that no competing interests exist.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0236496