The pathogenicity of coagulase negative staphylococcus in the presence of silicone rubber implants

Coagulase negative staphylococci have long been thought to be harmless skin commensals. However they are now recognised as important pathogens in patients who have undergone insertion of prosthetic devices. We present three patients with infection following the insertion of silicone polymer prosthes...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of plastic surgery Vol. 40; no. 1; pp. 94 - 96
Main Authors Wong, P.T.L., Nield, Dalia V., Khoo, C.T.K.
Format Journal Article
LanguageEnglish
Published Oxford Elsevier Ltd 1987
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Coagulase negative staphylococci have long been thought to be harmless skin commensals. However they are now recognised as important pathogens in patients who have undergone insertion of prosthetic devices. We present three patients with infection following the insertion of silicone polymer prostheses, in whom a coagulase negative staphylococcus was the pathogen. All responded to antibiotic treatment. It is important to alert the bacteriologist to the presence of an implanted prosthesis when wound swabs are sent from an area showing clinical signs of infection. The coagulase negative staphylococci may otherwise be regarded falsely as merely skin contaminants.
Bibliography:ObjectType-Case Study-2
SourceType-Scholarly Journals-1
ObjectType-Feature-4
content type line 23
ObjectType-Report-1
ObjectType-Article-3
ISSN:0007-1226
1465-3087
DOI:10.1016/0007-1226(87)90018-X