An evoked response study of the first-order difference tone in man
The amplitude of the N1-P2 component of a response evoked by a 250 Hz test stimulus presented once each 5 sec was measured. Interposed at a rate of one per sec were either 1) a 4000 Hz tone, 2) a 4000 Hz and a 4250 Hz tone presented simultaneously which generated within the ear an audible 250 Hz dif...
Saved in:
Published in | Acta oto-laryngologica Vol. 80; no. 1-2; p. 1 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
England
01.01.1975
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Summary: | The amplitude of the N1-P2 component of a response evoked by a 250 Hz test stimulus presented once each 5 sec was measured. Interposed at a rate of one per sec were either 1) a 4000 Hz tone, 2) a 4000 Hz and a 4250 Hz tone presented simultaneously which generated within the ear an audible 250 Hz difference tone, or 3) a 250 Hz tone. The results indicated that the N1-P2 component when preceded by the 4000 Hz plus 4250 Hz stimulus pair was larger than when preceded by a 250 Hz tone, but smaller than when preceded by a 4000 Hz tome. Apparently the processing of the difference tone is unlike that of a sinusoid of the same frequency or that of a high frequency sinusoid which participated in the generation of the difference tone. Parallel electrophysiological data from cochlear recordings are discussed. |
---|---|
ISSN: | 0001-6489 |
DOI: | 10.3109/00016487509121293 |