Simple immersion of filter devices into an urokinase solution prevents fibrin net formation during carotid artery stenting

Slow‐flow phenomenon is frequently observed during carotid artery stenting (CAS) with a filter embolic protection device. It results in technical difficulties and can lead to adverse neurological events. Flow impairment is thought to be caused by plaque entrapped by the filter and/or blood coagulati...

Full description

Saved in:
Bibliographic Details
Published inJournal of biomedical materials research. Part B, Applied biomaterials Vol. 95B; no. 1; pp. 171 - 176
Main Authors Hamada, Kazuhide, Matsushima, Satoshi, Toma, Naoki, Totani, Takahiko, Toda, Mitsuaki, Ogawa, Satoru, Asakura, Fumio, Sakaida, Hiroshi, Iwata, Hiroo, Taki, Waro
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.10.2010
Wiley-Blackwell
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Slow‐flow phenomenon is frequently observed during carotid artery stenting (CAS) with a filter embolic protection device. It results in technical difficulties and can lead to adverse neurological events. Flow impairment is thought to be caused by plaque entrapped by the filter and/or blood coagulation on the filter. Characteristics of heparin‐ or urokinase‐treated polyurethanes were analyzed by surface plasmon resonance, and the fibrinolytic activity of the urokinase‐treated filter of Angioguard XP was estimated by the fibrin plate assay. A filter membrane of Angioguard XP protection device was treated with a heparin or urokinase solution. In clinical studies, six and nine patients were treated by CAS using Angioguard XP modified with heparin and urokinase, respectively. Filter membranes were examined by scanning electron microscopy (SEM). From in vitro studies, it appeared that urokinase adsorbed and remained on the Angioguard XP filter, and its fibrinolytic activity was demonstrated even after washing with saline; heparin, however, was easily washed out from the surface. From clinical study, some filter pores were obstructed in all six patients in the heparin group and in three patients in the urokinase group. Fibrin net was found on the filter in five of six patients in the heparin group and in one of nine patients in the urokinase group. Treatment of an Angioguard XP filter with a urokinase solution is effective in preventing pore occlusion and may reduce occurrence of the slow‐flow phenomenon. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010.
Bibliography:ark:/67375/WNG-LQNRDXZD-Z
ArticleID:JBM31699
istex:626614D5297B194F81C647D01C6B6BD5BA94FEB0
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:1552-4973
1552-4981
1552-4981
DOI:10.1002/jbm.b.31699