Long-Term Follow-Up Results of a Second-Generation Cementless Femoral Prosthesis with a Collar and Straight Distal Fixation Channels

We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip ar...

Full description

Saved in:
Bibliographic Details
Published inYonsei medical journal Vol. 53; no. 1; pp. 186 - 192
Main Authors Han, Chang Wook, Yang, Ick Hwan, Lee, Hye Yeon, Han, Chang Dong
Format Journal Article
LanguageEnglish
Published Korea (South) Yonsei University College of Medicine 01.01.2012
연세대학교의과대학
Subjects
Online AccessGet full text
ISSN0513-5796
1976-2437
1976-2437
DOI10.3349/ymj.2012.53.1.186

Cover

More Information
Summary:We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems were followed for more than 10 years. Ninety-four hips in 80 patients were available for clinical and radiologic analysis. The mean age at the time of surgery was 47 years, and the mean duration of follow-up was 14.3 years. The mean Harris hip scores had improved from 58 points to 88 points at the time of the 10-year follow-up. Activity-related thigh pain was reported in nine hips (10%). At the last follow-up, 93 stems (99%) were biologically stable and one stem (1%) was revised because of loosening. No hip had distal diaphyseal osteolysis. Proximal femoral stress-shielding was reported in 86 hips (91%). We found no significant relationship between collar-calcar contact and thigh pain, stem fixation status, or stress-shielding. The cumulative survival of the femoral stem was 99% (95% confidence interval, 98-100%) after 10 years. The long-term results of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels were satisfactory; however, the high rate of proximal stress-shielding and the minimal effect of the collar indicate the need for some changes in the stem design.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
http://www.eymj.org/DOIx.php?id=10.3349/ymj.2012.53.1.186
G704-000409.2012.53.1.034
ISSN:0513-5796
1976-2437
1976-2437
DOI:10.3349/ymj.2012.53.1.186