A chiral high-performance liquid chromatography–tandem mass spectrometry method for the stereospecific determination of morinidazole in human plasma

•Baseline separation of morinidazole enantiomers was achieved on a cellulose chiral stationary phase column using a high proportion of organic phase.•d4-Morinidazole was synthesized as the internal standard to compensate for matrix effects and variables during sample preparation.•The analysis time w...

Full description

Saved in:
Bibliographic Details
Published inJournal of chromatography. B, Analytical technologies in the biomedical and life sciences Vol. 961; pp. 49 - 55
Main Authors Zhong, Kan, Gao, Zhiwei, Li, Qin, Zhong, Dafang, Chen, Xiaoyan
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 15.06.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:•Baseline separation of morinidazole enantiomers was achieved on a cellulose chiral stationary phase column using a high proportion of organic phase.•d4-Morinidazole was synthesized as the internal standard to compensate for matrix effects and variables during sample preparation.•The analysis time was short by using a flow rate gradient.•The method shows advantages of high selectivity and reproducibility.•The method was successfully applied to clinical stereoselective pharmacokinetics study of morinidazole. Morinidazole is a novel 5-nitroimidazole derivative used for the treatment of amoebiasis, trichomoniasis, and anaerobic bacterial infections. Morinidazole possesses a chiral carbon and is clinically administered as a racemate. In the present study, an enantioselective and sensitive liquid chromatography–tandem mass spectrometry method of determining morinidazole enantiomers in human plasma was developed and validated to characterize the stereoselective pharmacokinetics. Plasma samples were processed by liquid–liquid extraction using tert-butyl methyl ether. Chiral separation was optimized within 8.5min on a cellulose column using an isocratic mobile phase of methanol/water (80:20, v/v). Detection was using mass spectrometry in multiple reaction monitoring mode, using the transitions of m/z 271→144 for morinidazole enantiomers, and m/z 275→148 for d4-morinidazole (internal standard). The calibration curves were linear over 5.00–6000ng/mL for each enantiomer. The lower limit of quantification for each enantiomer was established at 5.00ng/mL. Intra- and inter-day precisions were less than 6.4% for each enantiomer in terms of relative standard deviation, and accuracies were between −2.5% and 6.4% in terms of relative error for each enantiomer. No chiral inversion was observed during sample storage, preparation procedure and analysis. Major glucuronide and sulfate conjugates were not observed to interfere with the determination of morinidazole enantiomers. The method was applied to study the stereoselective pharmacokinetics of morinidazole in humans. Moderate stereoselectivity was observed in healthy subjects and patients with severe renal impairment.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ObjectType-Article-2
ObjectType-Feature-1
ISSN:1570-0232
1873-376X
1873-376X
DOI:10.1016/j.jchromb.2014.04.049