The laryngeal mask airway in the difficult paediatric airway: an assessment of positioning and use in fibreoptic intubation

Summary The laryngeal mask airway (LMA) was used in 34 children who presented with difficult airways and difficulty in intubation. All 34 children were a grade 3 or grade 4 Cormack and Leehane view at conventional laryngoscopy. The laryngeal mask airway was used as part of the anaesthetic technique....

Full description

Saved in:
Bibliographic Details
Published inPediatric anesthesia Vol. 10; no. 1; pp. 53 - 58
Main Author Walker, Robert W.M.
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Science Ltd 01.01.2000
Blackwell
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Summary The laryngeal mask airway (LMA) was used in 34 children who presented with difficult airways and difficulty in intubation. All 34 children were a grade 3 or grade 4 Cormack and Leehane view at conventional laryngoscopy. The laryngeal mask airway was used as part of the anaesthetic technique. It was either used as the method of airway maintenance during a short procedure or as an aid to fibreoptic intubation. The results of its use in this group of patients showed that overall a good airway was obtained in 73% of patients and an adequate airway in 27%, and in no patient was a poor airway obtained. The fibreoptic positioning of the LMA, taken from the distal aperture of the laryngeal mask airway showed that, overall, in 29.5% of patients a full view of the glottis (grade 1) was obtained, in 29.5% of patients a partial view of the glottis (grade 2) was obtained and in 41% a view of the epiglottis only (grade 3) was obtained. In no patient was a view excluding the epiglottis obtained. In children with a mucopolysaccharide disorder, the number of children who had a grade 3 view increased to 54%. Children with a disorder other than mucopolysaccharidosis had a grade 3 view in only 17% of cases. Children with mucopolysaccharidoses had a grade 1 view in only 14% of cases compared with 58% in the group with other disorders. Of the 34 patients, 21 patients were intubated on 31 separate occasions. There were no failures. The complications of the fibreoptic intubation technique described are outlined.
Bibliography:ark:/67375/WNG-HS111SBK-H
istex:80A611E767DAFDA0122EB830D4E5D17D0E852C2E
ArticleID:PAN425
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1155-5645
1460-9592
DOI:10.1046/j.1460-9592.2000.00425.x