Accuracy and reproducibility of manual and semiautomated quantification of MS lesions by MRI
Purpose To evaluate the accuracy, reproducibility, and speed of two semiautomated methods for quantifying total white matter lesion burden in multiple sclerosis (MS) patients with respect to manual tracing and to other methods presented in recent literature. Materials and Methods Two methods involvi...
Saved in:
Published in | Journal of magnetic resonance imaging Vol. 17; no. 3; pp. 300 - 308 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
New York
Wiley Subscription Services, Inc., A Wiley Company
01.03.2003
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Purpose
To evaluate the accuracy, reproducibility, and speed of two semiautomated methods for quantifying total white matter lesion burden in multiple sclerosis (MS) patients with respect to manual tracing and to other methods presented in recent literature.
Materials and Methods
Two methods involving the use of MRI for semiautomated quantification of total lesion burden in MS patients were examined. The first method, geometrically constrained region growth (GEORG), requires user specification of lesion location. The second technique, directed multispectral segmentation (DMSS), requires only the location of a single exemplar lesion. Test data sets included both clinical MS data and MS brain phantoms.
Results
The mean processing times were 60 minutes for manual tracing, 10 minutes for region growth, and 3 minutes for directed segmentation. Intra‐ and interoperator coefficients of variation (CVs) were 5.1% and 16.5% for manual tracing, 1.4% and 2.3% for region growth, and 1.5% and 5.2% for directed segmentation. The average deviations from manual tracing were 9% for region growth and 5.7% for directed segmentation.
Conclusion
Both semiautomated methods were shown to have a significant advantage over manual tracing in terms of speed and precision. The accuracy of both methods was acceptable, given the high variability of the manual results. J. Magn. Reson. Imaging 2003;17:300–308. © 2003 Wiley‐Liss, Inc. |
---|---|
Bibliography: | istex:2BE9F24DF1E01129DBC880BD64691FD84D3D3390 ArticleID:JMRI10258 ark:/67375/WNG-FGGSWX24-Q ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1053-1807 1522-2586 |
DOI: | 10.1002/jmri.10258 |