Influence of simulated bone-implant contact and implant diameter on secondary stability: a resonance frequency in vitro study

Objectives This study tested the hypothesis of no differences in resonance frequency for standardized amounts of simulated bone–implant contact around implants with different diameters. In addition, it was evaluated if resonance frequency is able to detect a difference between stable and rotation mo...

Full description

Saved in:
Bibliographic Details
Published inClinical oral implants research Vol. 25; no. 8; pp. 899 - 904
Main Authors Veltri, Mario, González-Martín, Oscar, Belser, Urs C.
Format Journal Article
LanguageEnglish
Published Denmark Blackwell Publishing Ltd 01.08.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives This study tested the hypothesis of no differences in resonance frequency for standardized amounts of simulated bone–implant contact around implants with different diameters. In addition, it was evaluated if resonance frequency is able to detect a difference between stable and rotation mobile (“spinning”) implants. Material and Methods Implants with diameters of 3.3, 4.1 and 4.8 mm were placed in a purposely designed metal mould where liquid polyurethane resin was then poured to obtain a simulated bone‐implant specimen. By regulating the mould, it was possible to create the following simulated bone–implant contact groups: 3.3 mm (198.6 mm2); 4.1 mm (198.8 mm2); 4.8 mm (200.2 mm2); 4.8 mm (231.7 mm2); 4.8 mm (294.7 mm2). Each group included 10 specimens. After resin setting, resonance frequency was measured. On the last group, measurements were repeated after establishing implant rotational mobility. One‐way ANOVA tests with post hoc comparisons, a Pearson's correlation coefficient and a t‐test for repeated measurements were used to evaluate statistically significant differences. Results Implants with different diameters but with the same amount of simulated osseointegration revealed no differences in resonance frequency. On the contrary, an increase of simulated bone–implant contact resulted in significantly higher resonance frequency. A clear direct linear correlation resulted between resonance frequency and simulated bone–implant contact. Furthermore, a significant difference resulted between resonance frequency measured before and after creation of rotational mobility. Conclusions Within the conditions of this study, the secondary stability was correlated with the simulated bone–implant contact. In addition, resonance frequency was able to discern between stable and rotation mobile implants.
Bibliography:School of Dental Medicine of the University of Geneva
istex:EB9B83E27D71814733B694A00B542D361AD4FB61
ark:/67375/WNG-SPDT6QPG-Z
ArticleID:CLR12195
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0905-7161
1600-0501
DOI:10.1111/clr.12195