Using the axis of rotation of polar navigator echoes to rapidly measure 3D rigid-body motion

An improved technique to prospectively correct three‐dimensional rigid‐body motion using polar spherical navigator (pNAV) echoes is presented. The technique is based on acquiring pNAVs of an object in a baseline and rotated position and determining the axis of rotation (AOR) between data sets, there...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 53; no. 1; pp. 150 - 158
Main Authors Costa, Andreu F., Petrie, Daniel W., Yen, Yi-Fen, Drangova, Maria
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.01.2005
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:An improved technique to prospectively correct three‐dimensional rigid‐body motion using polar spherical navigator (pNAV) echoes is presented. The technique is based on acquiring pNAVs of an object in a baseline and rotated position and determining the axis of rotation (AOR) between data sets, thereby reducing 3D rotations to a 2D, planar rotation. Finding the AOR is simplified by prerotating the baseline trajectory, which forces the axis to lie within a specific polar region of a spherical shell in k‐space. Orbital navigator echoes are interpolated from the pNAV data in planes orthogonal to the AOR and cross‐correlated to determine the 2D rotation. The rotation about the AOR is used in conjunction with its orientation to calculate the overall 3D rotation. The pNAV‐AOR technique was tested for its precision, accuracy, and processing speed in detecting compound rotations and translations of varying magnitude. In comparison to the spherical navigator echo technique, the pNAV‐AOR technique is noniterative, fast, and independent of rotation magnitude and direction. At low SNR, the technique can detect compound rotations to 0.5° accuracy in an estimated 100 msec, indicating that prospective 3D rigid‐body motion correction may be feasible with this technique. Magn Reson Med 53:150–158, 2005. © 2004 Wiley‐Liss, Inc.
Bibliography:Natural Sciences and Engineering Research Council of Canada
ArticleID:MRM20306
istex:B94C294B50903B77A6455CE4B9BA581999E112C6
ark:/67375/WNG-DHRTKVQD-G
Ontario Research and Development Challenge Fund
Canadian Institutes of Health Research - No. MGP-49536
Whitaker Foundation - No. RG-00-0409
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0740-3194
1522-2594
DOI:10.1002/mrm.20306