Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study

We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm...

Full description

Saved in:
Bibliographic Details
Published inJournal of Zhejiang University. B. Science Vol. 6; no. 5; pp. 438 - 445
Main Author 高诺 朱善安 贺斌
Format Journal Article
LanguageEnglish
Published China Springer Nature B.V 01.05.2005
School of Electrical Engineering, Zhejiang University, Hangzhou 310027, China%Department of Biomedical Engineering, University of Minnesota, MN, USA
Zhejiang University Press
Subjects
Online AccessGet full text
ISSN1673-1581
1862-1783
DOI10.1631/jzus.2005.B0438

Cover

More Information
Summary:We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach.Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model.Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245±0.0068 and 8.9997%±0.0084%, for hemorrhagic stroke, and 0.6748±0.0197 and 8.8986%±0.0089%,for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans.
Bibliography:R445
33-1356/Q
R816.1
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1673-1581
1862-1783
DOI:10.1631/jzus.2005.B0438