Novel, Precise, Accurate Ion-Pairing Method to Determine the Related Substances of the Fondaparinux Sodium Drug Substance: Low-Molecular-Weight Heparin

Fondaparinux sodium is a synthetic low-molecular-weight heparin (LMWH). This medication is an anticoagulant or a blood thinner, prescribed for the treatment of pulmonary embolism and prevention and treatment of deep vein thrombosis. Its determination in the presence of related impurities was studied...

Full description

Saved in:
Bibliographic Details
Published inScientia pharmaceutica Vol. 84; no. 1; pp. 19 - 40
Main Authors Deshpande, Amol A, Madhavan, P, Deshpande, Girish R, Chandel, Ravi Kumar, Yarbagi, Kaviraj M, Joshi, Alok R, Moses Babu, J, Murali Krishna, R, Rao, I M
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 01.01.2016
The Austrian Journal of Pharmaceutical Sciences
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Fondaparinux sodium is a synthetic low-molecular-weight heparin (LMWH). This medication is an anticoagulant or a blood thinner, prescribed for the treatment of pulmonary embolism and prevention and treatment of deep vein thrombosis. Its determination in the presence of related impurities was studied and validated by a novel ion-pair HPLC method. The separation of the drug and its degradation products was achieved with the polymer-based PLRPs column (250 mm × 4.6 mm; 5 μm) in gradient elution mode. The mixture of 100 mM n-hexylamine and 100 mM acetic acid in water was used as buffer solution. Mobile phase A and mobile phase B were prepared by mixing the buffer and acetonitrile in the ratio of 90:10 (v/v) and 20:80 (v/v), respectively. Mobile phases were delivered in isocratic mode (2% B for 0-5 min) followed by gradient mode (2-85% B in 5-60 min). An Evaporative Light Scattering Detector (ELSD) was connected to the LC system to detect the responses of chromatographic separation. Further, the drug was subjected to stress studies for acidic, basic, oxidative, photolytic, and thermal degradations as per ICH guidelines and the drug was found to be labile in acid, base hydrolysis, and oxidation, while stable in neutral, thermal, and photolytic degradation conditions. The method provided linear responses over the concentration range of the LOQ to 0.30% for each impurity with respect to the analyte concentration of 12.5 mg/mL, and regression analysis showed a correlation coefficient value (r(2)) of more than 0.99 for all the impurities. The LOD and LOQ were found to be 1.4 µg/mL and 4.1 µg/mL, respectively, for fondaparinux. The developed ion-pair method was validated as per ICH guidelines with respect to accuracy, selectivity, precision, linearity, and robustness.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0036-8709
2218-0532
DOI:10.3797/scipharm.1505-20