Performance of a non-load-bearing steel stud gypsum board wall assembly: Experiments and modelling

A gypsum wall assembly was exposed to an intense real‐scale compartment fire. For the wall assembly, temperatures were measured at the exposed face, within the stud cavity, and at the unexposed face during the fire exposure. Total heat flux gauges were used to measure the temporal variation of the e...

Full description

Saved in:
Bibliographic Details
Published inFire and materials Vol. 31; no. 5; pp. 297 - 310
Main Authors Manzello, Samuel L., Gann, Richard G., Kukuck, Scott R., Prasad, Kuldeep, Jones, Walter W.
Format Journal Article
LanguageEnglish
Published Chichester, UK John Wiley & Sons, Ltd 01.08.2007
Wiley
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A gypsum wall assembly was exposed to an intense real‐scale compartment fire. For the wall assembly, temperatures were measured at the exposed face, within the stud cavity, and at the unexposed face during the fire exposure. Total heat flux gauges were used to measure the temporal variation of the energy incident on the walls, and cameras, both visual and infrared, were used to image the unexposed face of the wall assembly during the fire exposure. The behaviour of the wall assembly under the fire load is discussed as are current model results for a simulation of the fire test. Copyright © 2006 John Wiley & Sons, Ltd.
Bibliography:istex:E8AD82D1725CF8B6E0A4901A369D3F512124CFD0
ark:/67375/WNG-8GMR9ZC0-P
ArticleID:FAM939
Official contribution of the National Institute of Standards and Technology. Not subject to copyright in the United States of America.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0308-0501
1099-1018
DOI:10.1002/fam.939