Post column derivatisation analyses review. Is post-column derivatisation incompatible with modern HPLC columns?

Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction...

Full description

Saved in:
Bibliographic Details
Published inAnalytica chimica acta Vol. 889; pp. 58 - 70
Main Authors Jones, Andrew, Pravadali-Cekic, Sercan, Dennis, Gary R., Shalliker, R. Andrew
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 19.08.2015
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC. We reviewed 87 PCD methods published from 2009 to 2014. We restricted our review to methods published between 2009 and 2014, because we were interested in the uptake of PCD methods in UHPLC environments. Our review focused on a range of system parameters including: column dimensions, stationary phase and particle size, as well as the geometry of the reaction loop. The most commonly used column in the methods investigated was not in fact a modern UHPLC version with sub-2-micron, (or even sub-3-micron) particles, but rather, work-house columns, such as, 250 × 4.6 mm i.d. columns packed with 5 μm C18 particles. Reaction loops were varied, even within the same type of analysis, but the majority of methods employed loop systems with volumes greater than 500 μL. A second part of this review illustrated briefly the effect of dead volume on column performance. The experiment evaluated the change in resolution and separation efficiency of some weak to moderately retained solutes on a 250 × 4.6 mm i.d. column packed with 5 μm particles. The data showed that reaction loops beyond 100 μL resulted in a very serious loss of performance. Our study concluded that practitioners of PCD methods largely avoid the use of UHPLC-type column formats, so yes, very much, PCD is incompatible with the modern HPLC column. [Display omitted] •Post-column derivatisation methods are a powerful class of detection techniques.•84 methods were reviewed, which were published since 2009.•Post column dead volume associated with PCD methods causes a serious loss in separation efficiency.•We discovered that most users do not use columns packed with particles less than 5 μm.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-3
content type line 23
ObjectType-Review-1
ISSN:0003-2670
1873-4324
DOI:10.1016/j.aca.2015.07.003